Effect of locator abutment height on the retentive values of pink locator attachments: An in vitro study.
Journal of Prosthetic Dentistry 2017 Februrary
STATEMENT OF PROBLEM: Currently, no guidelines exist to help in the selection of Locator abutments for implants at different heights.
PURPOSE: The purpose of this in vitro study was to evaluate the effect of the differential heights of pairs of Locator abutments on the retention of overdentures after 6 months of simulated function.
MATERIAL AND METHODS: In vitro testing was performed with 4 sets of average-sized edentulous mandible analogs with 2 implants placed in the canine positions. There were 10 specimens in each of the 4 groups, with a total sample size of 40. Four groups of 2 implant-retained overdentures were fabricated, with Locator attachments at different vertical levels with differences of 0, 2, 4, and 6 mm. The overdentures were subjected to simulated function for a period corresponding to 6 months of clinical service and then tested with a universal testing machine for changes in peak load-to-dislodgement. The data were analyzed using 1-way ANOVA followed by the Tukey honest significant differences test (α=.05).
RESULTS: Varying the heights of Locator abutments had a statistically significant effect on the retentive values of the pink Locator attachments after 6 months of simulated function (F=7.342, P=.001). The peak load-to-dislodgement ranged from 32.3 N (95% confidence interval [CI]: 26.0 to 38.6) for group 0 mm to 53.6 N (95% CI: 46.3 to 60.8) for group 6 mm. When the difference in Locator abutment heights was 2 and 4 mm, the peak load was 37.1 N (95% CI: 32.3 to 42.0) and 41.9 N (95% CI: 31.2 to 52.7). Statistical analysis revealed that the retention of group 0 mm and group 2 mm was significantly lower than group 6 mm. The retention of group 4 mm was not significantly different from groups 0 mm, 2 mm, or 6 mm.
CONCLUSIONS: Although significant differences were found among the groups, these differences were small and may not be clinically detectable.
PURPOSE: The purpose of this in vitro study was to evaluate the effect of the differential heights of pairs of Locator abutments on the retention of overdentures after 6 months of simulated function.
MATERIAL AND METHODS: In vitro testing was performed with 4 sets of average-sized edentulous mandible analogs with 2 implants placed in the canine positions. There were 10 specimens in each of the 4 groups, with a total sample size of 40. Four groups of 2 implant-retained overdentures were fabricated, with Locator attachments at different vertical levels with differences of 0, 2, 4, and 6 mm. The overdentures were subjected to simulated function for a period corresponding to 6 months of clinical service and then tested with a universal testing machine for changes in peak load-to-dislodgement. The data were analyzed using 1-way ANOVA followed by the Tukey honest significant differences test (α=.05).
RESULTS: Varying the heights of Locator abutments had a statistically significant effect on the retentive values of the pink Locator attachments after 6 months of simulated function (F=7.342, P=.001). The peak load-to-dislodgement ranged from 32.3 N (95% confidence interval [CI]: 26.0 to 38.6) for group 0 mm to 53.6 N (95% CI: 46.3 to 60.8) for group 6 mm. When the difference in Locator abutment heights was 2 and 4 mm, the peak load was 37.1 N (95% CI: 32.3 to 42.0) and 41.9 N (95% CI: 31.2 to 52.7). Statistical analysis revealed that the retention of group 0 mm and group 2 mm was significantly lower than group 6 mm. The retention of group 4 mm was not significantly different from groups 0 mm, 2 mm, or 6 mm.
CONCLUSIONS: Although significant differences were found among the groups, these differences were small and may not be clinically detectable.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app