Central corneal thickness in glaucoma.
Current Opinion in Ophthalmology 2017 March
PURPOSE OF REVIEW: The purpose of this review is to summarize the role of central corneal thickness (CCT) in the clinical management of a glaucoma patient.
RECENT FINDINGS: The prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation.
SUMMARY: The clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.
RECENT FINDINGS: The prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation.
SUMMARY: The clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app