Interobserver reproducibility of radiographic evaluation of lumbar spine instability.
Einstein 2016
OBJECTIVE:: To measure the interobserver reproducibility of the radiographic evaluation of lumbar spine instability.
METHODS:: Measurements of the dynamic radiographs of the lumbar spine in lateral view were performed, evaluating the anterior translation and the angulation among the vertebral bodies. The tests were evaluated at workstations of the organization, through the Carestream Health Vue RIS (PACS), version 11.0.12.14 Inc. 2009© system.
RESULTS:: Agreement in detecting cases of radiographic instability among the observers varied from 88.1 to 94.4%, and the agreement coefficients AC1 were all above 0.8, indicating excellent agreement.
CONCLUSION:: The interobserver analysis performed among orthopedic surgeons with different levels of training in dynamic radiographs of the spine obtained high reproducibility and agreement. However, some factors, such as the manual method of measurement and the presence of vertebral osteophytes, might have generated a few less accurate results in this comparative evaluation of measurements.
OBJETIVO:: Mensurar a reprodutibilidade interobservadores da avaliação radiográfica da instabilidade da coluna lombar.
MÉTODOS:: Foram realizadas mensurações das radiografias dinâmicas de coluna lombar na incidência em perfil, avaliando-se a translação anterior e a angulação entre os corpos vertebrais. Os exames foram avaliados em workstations da própria instituição, por meio do sistema Vue RIS (PACS) da Carestream Health, versão 11.0.12.14 Inc. 2009©.
RESULTADOS:: A proporção de concordância em detecção de casos de instabilidade radiográfica entre os observadores variou de 88,1 a 94,4%, e os coeficientes de concordância AC1 estiveram todos acima de 0,8, indicando concordância excelente.
CONCLUSÃO:: A análise interobservadores realizada entre médicos ortopedistas com diferentes níveis de treinamento em radiografias dinâmicas da coluna vertebral obteve elevada reprodutibilidade e concordância. No entanto, alguns fatores, como método manual de aferição e a presença de osteófitos vertebrais, podem ter gerado alguns resultados menos consistentes nessa avaliação comparativa de medidas.
METHODS:: Measurements of the dynamic radiographs of the lumbar spine in lateral view were performed, evaluating the anterior translation and the angulation among the vertebral bodies. The tests were evaluated at workstations of the organization, through the Carestream Health Vue RIS (PACS), version 11.0.12.14 Inc. 2009© system.
RESULTS:: Agreement in detecting cases of radiographic instability among the observers varied from 88.1 to 94.4%, and the agreement coefficients AC1 were all above 0.8, indicating excellent agreement.
CONCLUSION:: The interobserver analysis performed among orthopedic surgeons with different levels of training in dynamic radiographs of the spine obtained high reproducibility and agreement. However, some factors, such as the manual method of measurement and the presence of vertebral osteophytes, might have generated a few less accurate results in this comparative evaluation of measurements.
OBJETIVO:: Mensurar a reprodutibilidade interobservadores da avaliação radiográfica da instabilidade da coluna lombar.
MÉTODOS:: Foram realizadas mensurações das radiografias dinâmicas de coluna lombar na incidência em perfil, avaliando-se a translação anterior e a angulação entre os corpos vertebrais. Os exames foram avaliados em workstations da própria instituição, por meio do sistema Vue RIS (PACS) da Carestream Health, versão 11.0.12.14 Inc. 2009©.
RESULTADOS:: A proporção de concordância em detecção de casos de instabilidade radiográfica entre os observadores variou de 88,1 a 94,4%, e os coeficientes de concordância AC1 estiveram todos acima de 0,8, indicando concordância excelente.
CONCLUSÃO:: A análise interobservadores realizada entre médicos ortopedistas com diferentes níveis de treinamento em radiografias dinâmicas da coluna vertebral obteve elevada reprodutibilidade e concordância. No entanto, alguns fatores, como método manual de aferição e a presença de osteófitos vertebrais, podem ter gerado alguns resultados menos consistentes nessa avaliação comparativa de medidas.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app