Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Patient-centered design criteria for wearable seizure detection devices.

INTRODUCTION: Epilepsy is a common neurological condition. Seizure diary reports and patient- or caregiver-reported seizure counts are often inaccurate and underestimated. Many caregivers express stress and anxiety about the patient with epilepsy having seizures when they are not present. Therefore, a need exists for the ability to recognize and/or detect a seizure in the home setting. However, few studies have inquired on detection device features that are important to patients and their caregivers.

METHODS: A survey instrument utilizing a population of patients and caregivers was created to obtain information on the design criteria most desired for patients with epilepsy in regard to wearable devices.

RESULTS: One thousand one hundred sixty-eight responses were collected. Respondents thought that sensors for muscle signal (61.4%) and heart rate (58.0%) would be most helpful followed by the O2 sensor (41.4%). There was more interest in these three sensor types than for an accelerometer (25.5%). There was very little interest in a microphone (8.9%), galvanic skin response sensor (8.0%), or a barometer (4.9%). Based on a rating scale of 1-5 with 5 being the most important, respondents felt that "detecting all seizures" (4.73) is the most important device feature followed by "text/email alerts" (4.53), "comfort" (4.46), and "battery life" (4.43) as an equally important group of features. Respondents felt that "not knowing device is for seizures" (2.60) and "multiple uses" (2.57) were equally the least important device features. Average ratings differed significantly across age groups for the following features: button, multiuse, not knowing device is for seizures, alarm, style, and text ability. The p-values were all<0.002. Eighty-two point five percent of respondents [95% confidence interval: 80.0%, 84.7%] were willing to pay more than $100 for a wearable seizure detection device, and 42.8% of respondents [95% confidence interval: 39.8%, 45.9%] were willing to pay more than $200.

CONCLUSIONS: Our survey results demonstrated that patients and caregivers have design features that are important to them in regard to a wearable seizure detection device. Overall, the ability to detect all seizures rated highest among respondents which continues to be an unmet need in the community with epilepsy in regard to seizure detection. Additional uses for a wearable were not as important. Based on our results, it is important that an alert (via test and/or email) for events be a portion of the system. A reasonable price point appears to be around $200 to $300. An accelerometer was less important to those surveyed when compared with the use of heart rate, oxygen saturation, or muscle twitches/signals. As further products become developed for use in other health arenas, it will be important to consider patient and caregiver desires in order to meet the need and address the gap in devices that currently exist.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app