We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
Clinical evaluation of a mini locking plate system for fracture repair of the radius and ulna in miniature breed dogs.
Veterinary and Comparative Orthopaedics and Traumatology : V.C.O.T 2016 November 24
OBJECTIVES: To retrospectively evaluate the effectiveness of a novel 1.2 mm mini locking plate system in treating fractures of the radius and ulna in miniature breed dogs.
METHODS: Medical records and radiographs of miniature breed dogs with fractures treated with a 1.2 mm mini locking plate system were reviewed. The inclusion criteria were: body weight of 2.5 kg or less, transverse or short oblique fracture of the radius and ulna, and treatment with a mini locking plate system as the sole method of fixation. For each patient, data including signalment, time to radiographic union, use of bone graft or other agents, and previous repair attempts were recorded. The outcome and complications were determined from clinical and radiographic follow-up examinations.
RESULTS: Fourteen cases with a mean radial width of 4.5 mm (± 0.8 mm) were included into this study. The fractures healed without failure of fixation in all cases. Mean time to adequate radiographic union was 8.4 weeks (± 2.6 weeks). Major complications were not seen in any of the cases, and minor complications occurred in three of the cases. Limb function was graded as 'normal' in 10 cases and 'occasional lameness' in four cases.
CLINICAL SIGNIFICANCE: The mini locking system evaluated in this study was an effective treatment method for radial and ulnar fractures in miniature breed dogs with a radial width smaller than 5.5 mm.
METHODS: Medical records and radiographs of miniature breed dogs with fractures treated with a 1.2 mm mini locking plate system were reviewed. The inclusion criteria were: body weight of 2.5 kg or less, transverse or short oblique fracture of the radius and ulna, and treatment with a mini locking plate system as the sole method of fixation. For each patient, data including signalment, time to radiographic union, use of bone graft or other agents, and previous repair attempts were recorded. The outcome and complications were determined from clinical and radiographic follow-up examinations.
RESULTS: Fourteen cases with a mean radial width of 4.5 mm (± 0.8 mm) were included into this study. The fractures healed without failure of fixation in all cases. Mean time to adequate radiographic union was 8.4 weeks (± 2.6 weeks). Major complications were not seen in any of the cases, and minor complications occurred in three of the cases. Limb function was graded as 'normal' in 10 cases and 'occasional lameness' in four cases.
CLINICAL SIGNIFICANCE: The mini locking system evaluated in this study was an effective treatment method for radial and ulnar fractures in miniature breed dogs with a radial width smaller than 5.5 mm.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app