Benefit of 3T Diffusion-weighted Imaging in Comparison to Contrast-enhanced MR Imaging for the Evaluation of Disseminated Lesions in Primary Malignant Brain Tumors.
Magnetic Resonance in Medical Sciences : MRMS 2017 July 11
PURPOSE: We aimed to determine whether 3T diffusion-weighted imaging (DWI) has an additive value relative to contrast-enhanced MR imaging for the detection of disseminated lesions in patients with primary malignant brain tumors.
METHODS: We included consecutive 12 patients with nodular disseminated lesions of primary malignant brain tumors that were confirmed by surgery or follow-up MR imaging. All underwent conventional MR imaging, DWI at b = 1000 and 3000 s/mm2 , post-contrast T1 -weighted and 3D gradient-echo imaging at 3T. For the largest lesion per person, two radiologists independently evaluated the presence of additional information on DWI compared with postcontrast MR images using a 4-point scoring system. On DW images, one radiologist measured the lesion-to-brain contrast ratio (LBCR).
RESULTS: Compared with postcontrast studies, radiologists 1 and 2, respectively, assigned more apparent lesion conspicuity in 2 (17%) and 1 (8%) DWI at b = 1000 s/mm2 and 4 (33%) and 5 (42%) DWI at b = 3000 s/mm2 studies. For one of them, the mean score was significantly higher for b = 3000 s/mm2 than b = 1000 s/mm2 (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm2 and b = 3000 s/mm2 was very good (κ = 0.85; 95% CI, 0.63-1.00) and excellent (κ = 0.93; 95% CI, 0.78-1.00), respectively. The mean LBCR was significantly higher for DWI at b = 3000 s/mm2 than DWI at b = 1000 s/mm2 (P < 0.01).
CONCLUSION: In the detection of disseminated lesions in patients with primary malignant brain tumors, 3T DWI has an additive value relative to contrast-enhanced MR imaging. DWI at b = 3000 s/mm2 may be more useful than DWI at b = 1000 s/mm2 .
METHODS: We included consecutive 12 patients with nodular disseminated lesions of primary malignant brain tumors that were confirmed by surgery or follow-up MR imaging. All underwent conventional MR imaging, DWI at b = 1000 and 3000 s/mm2 , post-contrast T1 -weighted and 3D gradient-echo imaging at 3T. For the largest lesion per person, two radiologists independently evaluated the presence of additional information on DWI compared with postcontrast MR images using a 4-point scoring system. On DW images, one radiologist measured the lesion-to-brain contrast ratio (LBCR).
RESULTS: Compared with postcontrast studies, radiologists 1 and 2, respectively, assigned more apparent lesion conspicuity in 2 (17%) and 1 (8%) DWI at b = 1000 s/mm2 and 4 (33%) and 5 (42%) DWI at b = 3000 s/mm2 studies. For one of them, the mean score was significantly higher for b = 3000 s/mm2 than b = 1000 s/mm2 (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm2 and b = 3000 s/mm2 was very good (κ = 0.85; 95% CI, 0.63-1.00) and excellent (κ = 0.93; 95% CI, 0.78-1.00), respectively. The mean LBCR was significantly higher for DWI at b = 3000 s/mm2 than DWI at b = 1000 s/mm2 (P < 0.01).
CONCLUSION: In the detection of disseminated lesions in patients with primary malignant brain tumors, 3T DWI has an additive value relative to contrast-enhanced MR imaging. DWI at b = 3000 s/mm2 may be more useful than DWI at b = 1000 s/mm2 .
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app