We have located links that may give you full text access.
Thrombotic Occlusion of Stent Graft Limbs due to Severe Angulation of Aortic Neck in Endovascular Repair of Abdominal Aortic Aneurysm.
Korean Circulation Journal 2016 September
Endovascular aneurysm repair (EVAR) is a safe alternative to open surgical repair for an abdominal aortic aneurysm. However, unfavorable aortic anatomy of the aneurysm has restricted the widespread use of EVAR. Anatomic limitation is most often related to characteristics of the proximal neck anatomy. In this report, we described a patient with a severely angulated proximal neck who underwent EVAR, but required repeat intervention because of thrombotic occlusion of stent graft limbs.