Add like
Add dislike
Add to saved papers

Low-drift nozzles vs. standard nozzles for pesticide application in the biological efficacy trials of pesticides in apple pest and disease control.

The coarse spray air-induction nozzles have documented pesticide drift reducing potential and hence pose lower risk of environmental pollution than the standard fine spray hollow cone nozzles. However, it is questioned that use of the low-drift nozzles might not provide as effective crop protection as the standard nozzles. The objective of work was to assess the pest and disease control efficacy as affected by spray volume rate and nozzle type. The experiment was carried out in apple orchard, cv Jonagold/M26. The evaluated treatments were combinations of three spray volume rates: 250, 500 and 750lha-1 , and two types of nozzles: hollow cone nozzles generating very fine spray, and flat fan air induction nozzles producing coarse droplets. The biological performance of treatments was determined based on severity of diseases: apple scab (Venturia inaequalis), powdery mildew (Podosphaera leucotricha) and bull's eye rot (Pezicula spp.), as well as population or damage caused by pests: green apple aphid (Aphis pomi), rosy apple aphid (Dysaphis plantaginea Pass.), woolly apple aphid (Eriosoma lanigerum), apple rust mite (Aculus schlechtendali) and apple blossom weevil (Anthonomus pomorum L.). In general apple scab was equally controlled by all treatments. Only in the years of high infection pressure efficacy of powdery mildew control was better for fine spray nozzles and high volume rates. Green and rosy apple aphids were better controlled with higher volume rates, though significance of the advantage over the lower rates was occasional. No effect of spray quality on efficacy of aphid and mite control was found for any spray volume rate. Better control of apple blossom weevil and woolly apple aphid was achieved with the high spray volume rate providing heavy coverage to the point of run-off. The air induction nozzles having drift reducing potential are biologically efficacious alternative to conventional hollow cone nozzles.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app