Usage of personal music players in adolescents and its association with noise-induced hearing loss: A cross-sectional analysis of Ohrkan cohort study data.
International Journal of Audiology 2017 January
OBJECTIVE: To describe personal music player (PMP) usage among adolescents, sociodemographic determinants and association with audiometric notches.
DESIGN: Audiometric evaluation to assess hearing status, and standardized questionnaires to evaluate PMP listening behaviors, leisure noise exposures and self-reported hearing loss symptoms. Sociodemographic information was collected using a parent questionnaire. Noise exposure by PMP usage equivalent for a 40 h week was estimated based on self-reported volume and duration of use.
STUDY SAMPLE: A total of 2143 students (54% females) attending 9th grade in Regensburg, Germany, during 2009 to 2011.
RESULTS: Overall, 85% of the students reported using PMPs. Exposure level exceeded 80 dB(A) in approximately one third, and 85 dB(A) in one quarter, of those who used PMP. An audiometric notch was found in 2.3% of participants, but was not significantly associated with higher PMP exposure.
CONCLUSIONS: PMP exposure above the occupational limits of 80 and 85 dB(A) set by the Directive 2003/10/EC may be a risk factor for developing noise-induced hearing loss. Educational measures to ameliorate high risk behaviors in PMP usage are needed, particularly for socially disadvantaged groups.
DESIGN: Audiometric evaluation to assess hearing status, and standardized questionnaires to evaluate PMP listening behaviors, leisure noise exposures and self-reported hearing loss symptoms. Sociodemographic information was collected using a parent questionnaire. Noise exposure by PMP usage equivalent for a 40 h week was estimated based on self-reported volume and duration of use.
STUDY SAMPLE: A total of 2143 students (54% females) attending 9th grade in Regensburg, Germany, during 2009 to 2011.
RESULTS: Overall, 85% of the students reported using PMPs. Exposure level exceeded 80 dB(A) in approximately one third, and 85 dB(A) in one quarter, of those who used PMP. An audiometric notch was found in 2.3% of participants, but was not significantly associated with higher PMP exposure.
CONCLUSIONS: PMP exposure above the occupational limits of 80 and 85 dB(A) set by the Directive 2003/10/EC may be a risk factor for developing noise-induced hearing loss. Educational measures to ameliorate high risk behaviors in PMP usage are needed, particularly for socially disadvantaged groups.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app