Add like
Add dislike
Add to saved papers

[Determination of tert-butyl alcohol in the air of the workplace by solvent desorption gas chromatography].

Objective: To establish solvent desorption gas chromatographic method for determination of tert-butyl alcohol in the air of the workplace. Methods: After tert-butyl alcohol in the air of the workplace collected with activated carbon tube and desorbed with 2% 2-propanol in CS2, and then separated with DB-FFAP capillary column and detected with flame ionization detector. Results: The linearity ranges were 0.6~2 264.0 mg/L. The limit of quantification was 0.6 mg/L. The determination has a good reproducibility. The intraassay and interassay precisions were 2.8%~3.2% and 3.8%~5.7%. The desorption efficiencies were 93.9%~98.1%. Absorption efficiencies were 95.8%~100.0%. The breakthrough volume was above 7.1 mg in 100mg activated carbon. The samples in activated carbon tube could be stored for at least 14 days at ambient temperature. Conclusion: The method is feasible for determination of tert-butyl alcohol in the air of the workplace.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app