We have located links that may give you full text access.
Pacing From the Right Ventricular Septum and Development of New Atrial Fibrillation in Paced Patients With Atrioventricular Block and Preserved Left Ventricular Function.
BACKGROUND: Whether pacing from the right ventricular (RV) septum improves prognosis is unclear. Furthermore, the clinical characteristics of patients who develop atrial fibrillation (AF) and cardiovascular events during long-term RV septal pacing have not been described.Methods and Results:We retrospectively evaluated the incidence of AF and cardiovascular events, including cardiac death, heart failure requiring hospitalization, or stroke, for a median of 4.0 years in 123 recipients of dual-chamber pacemakers implanted for atrioventricular block with preserved left ventricular function, who were free from AF before device implantation. AF developed in 30 patients (24%), and multivariable analysis suggested that the cumulative percentage of RV pacing was the only independent predictor of newly developed AF (hazard ratio: 1.19 for each 10% increment; 95% confidence interval: 1.04-1.41; P=0.01). Furthermore, older age, newly developed AF and a paced QRS duration ≥155 ms at pacemaker implantation were significant predictors of cardiovascular events.
CONCLUSIONS: RV septum pacing may induce AF in up to one-quarter of patients paced for atrioventricular block, according to the frequency of pacing. More importantly, in such patients, AF induced by RV pacing and a paced QRS duration ≥155 ms at pacemaker implantation are significantly associated with poor prognosis. Therefore, we recommend pacing from sites producing a paced QRS duration <155 ms and avoiding unnecessary RV pacing. (Circ J 2016; 80: 2302-2309).
CONCLUSIONS: RV septum pacing may induce AF in up to one-quarter of patients paced for atrioventricular block, according to the frequency of pacing. More importantly, in such patients, AF induced by RV pacing and a paced QRS duration ≥155 ms at pacemaker implantation are significantly associated with poor prognosis. Therefore, we recommend pacing from sites producing a paced QRS duration <155 ms and avoiding unnecessary RV pacing. (Circ J 2016; 80: 2302-2309).
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app