Add like
Add dislike
Add to saved papers

Tumor volume measurement error using computed tomography imaging in a phase II clinical trial in lung cancer.

To address the error introduced by computed tomography (CT) scanners when assessing volume and unidimensional measurement of solid tumors, we scanned a precision manufactured pocket phantom simultaneously with patients enrolled in a lung cancer clinical trial. Dedicated software quantified bias and random error in the [Formula: see text], and [Formula: see text] dimensions of a Teflon sphere and also quantified response evaluation criteria in solid tumors and volume measurements using both constant and adaptive thresholding. We found that underestimation bias was essentially the same for [Formula: see text], and [Formula: see text] dimensions using constant thresholding and had similar values for adaptive thresholding. The random error of these length measurements as measured by the standard deviation and coefficient of variation was 0.10 mm (0.65), 0.11 mm (0.71), and 0.59 mm (3.75) for constant thresholding and 0.08 mm (0.51), 0.09 mm (0.56), and 0.58 mm (3.68) for adaptive thresholding, respectively. For random error, however, [Formula: see text] lengths had at least a fivefold higher standard deviation and coefficient of variation than [Formula: see text] and [Formula: see text]. Observed [Formula: see text]-dimension error was especially high for some 8 and 16 slice CT models. Error in CT image formation, in particular, for models with low numbers of detector rows, may be large enough to be misinterpreted as representing either treatment response or disease progression.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app