We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
Analysis of the characteristics and management of critical values in a newborn tertiary center in China.
World Journal of Pediatrics : WJP 2017 Februrary
BACKGROUND: Critical value reporting has been widely adopted by hospitals throughout the world, but there were few reports about neonatal critical values. This study aimed to analyze characteristics of the neonatal critical values considered at our center and to provide information on improving neonatal intensive care.
METHODS: A retrospective study of critical values at a newborn tertiary center in China was conducted to assess neonatal critical values according to test, distribution, reporting time, patient outcome and the impact to the therapy.
RESULTS: In total, 926 critical values were recorded. Overall, 66.52% (616/926) of the items were reported within 24 hours of admission, 50.28% (465/926) during duty times and 54.75% (507/926) in the neonatal intensive care unit (NICU). The routine coagulation test was the most frequent source of critical values. Electrocardiography, blood gas analysis and therapeutic drug monitoring of drug levels were associated with the highest rates of treatment intervention (100%); routine coagulation tests were the lowest (23.14%). Sample quality was the main cause of false-positive critical values.
CONCLUSIONS: The incidence of neonatal critical values peaked during the first 24 hours post-admission and during duty periods. Each newborn center needs to enact rapid treatment guidelines to address common critical values in order to facilitate clinical interventions. Periodically reviewing critical values could help to optimize clinical practices.
METHODS: A retrospective study of critical values at a newborn tertiary center in China was conducted to assess neonatal critical values according to test, distribution, reporting time, patient outcome and the impact to the therapy.
RESULTS: In total, 926 critical values were recorded. Overall, 66.52% (616/926) of the items were reported within 24 hours of admission, 50.28% (465/926) during duty times and 54.75% (507/926) in the neonatal intensive care unit (NICU). The routine coagulation test was the most frequent source of critical values. Electrocardiography, blood gas analysis and therapeutic drug monitoring of drug levels were associated with the highest rates of treatment intervention (100%); routine coagulation tests were the lowest (23.14%). Sample quality was the main cause of false-positive critical values.
CONCLUSIONS: The incidence of neonatal critical values peaked during the first 24 hours post-admission and during duty periods. Each newborn center needs to enact rapid treatment guidelines to address common critical values in order to facilitate clinical interventions. Periodically reviewing critical values could help to optimize clinical practices.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app