We have located links that may give you full text access.
A Non-invasive Method for Assessment of Intravascular Fluid Status: Inferior Vena Cava Diameters and Collapsibility Index.
OBJECTIVE: To evaluate the correlation between central venous pressure (CVP) and inferior vena cava (IVC) diameters measured by ultrasonography (Ultrasound) in critically ill patients.
METHODS: Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultrasound. Patients younger than 18 years old, who were not intubated, who had an abdominal pressure greater than 12 mmHg, and/or who were admitted for trauma were excluded from the study.
RESULTS: Eighty three patients with a mean age of 73.6±11.2 years were enrolled. The most common diagnosis was sepsis (21 patients, 25.30%). IVC inspiration measurements were statistically significantly correlated with CVP measurements (p0.05, r: 0.1). IVC collapsibility measurements showed a negative correlation with CVP measurements (p<0.01, r: 0.68).
CONCLUSIONS: There is a strong correlation between CVP and IVC diameters and the collapsibility index. This is a new formula for evaluating CVP, based on our statistical analyses.
METHODS: Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultrasound. Patients younger than 18 years old, who were not intubated, who had an abdominal pressure greater than 12 mmHg, and/or who were admitted for trauma were excluded from the study.
RESULTS: Eighty three patients with a mean age of 73.6±11.2 years were enrolled. The most common diagnosis was sepsis (21 patients, 25.30%). IVC inspiration measurements were statistically significantly correlated with CVP measurements (p0.05, r: 0.1). IVC collapsibility measurements showed a negative correlation with CVP measurements (p<0.01, r: 0.68).
CONCLUSIONS: There is a strong correlation between CVP and IVC diameters and the collapsibility index. This is a new formula for evaluating CVP, based on our statistical analyses.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app