We have located links that may give you full text access.
Journal Article
Review
Comprehensive in vitro cardiac safety assessment using human stem cell technology: Overview of CSAHi HEART initiative.
Journal of Pharmacological and Toxicological Methods 2017 January
Recent increasing evidence suggests that the currently-used platforms in vitro IKr and APD, and/or in vivo QT assays are not fully predictive for TdP, and do not address potential arrhythmia (VT and/or VF) induced by diverse mechanisms of action. In addition, other cardiac safety liabilities such as functional dysfunction of excitation-contraction coupling (contractility) and structural damage (morphological damage to cardiomyocytes) are also major causes of drug attrition, but current in vitro assays do not cover all these liabilities. We organized the Consortium for Safety Assessment using Human iPS cells (CSAHi; https://csahi.org/en/), based on the Japan Pharmaceutical Manufacturers Association (JPMA), to verify the application of human iPS/ES cell-derived cardiomyocytes in drug safety evaluation. The main goal of the CSAHi HEART team has been to propose comprehensive screening strategies to predict a diverse range of cardiotoxicities by using recently introduced platforms (multi-electrode array (MEA), patch clamp, cellular impedance, motion field imaging [MFI], and Ca transient systems) while identifying the strengths and weaknesses of each. Our study shows that hiPS-CMs used in these platforms have pharmacological responses more relevant to humans in comparison with existent hERG, APD or Langendorff (MAPD/contraction) assays, and not only MEA but also other methods such as impedance, MFI, and Ca transient systems would offer paradigm changes of platforms for predicting drug-induced QT risk and/or arrhythmia or contractile dysfunctions. Furthermore, we propose a potential multi-parametric platform in which field potential (MEA)-Ca transient-contraction (MFI) could be evaluated simultaneously as an ideal novel platform for predicting a diversity of cardiac toxicities, namely whole effects on the excitation-contraction cascade.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app