Comparative Study
Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

Comparative analysis of 3D data accuracy of single tooth and full dental arch captured by different intraoral and laboratory digital impression systems.

The aim of this study was to compare the accuracy of digital impressions taken by different intraoral and laboratory scanners. For this purpose a synthetic jaw model with prepared tooth was scanned using intraoral scanning systems: 3D Progress (MHT S.P.A., IT - MHT Optic Research AG, CH); True Definition (3M ESPE, USA); Trios (3Shape A/S, DNK); CEREC AC Bluecam, CEREC Omnicam (Sirona Dental System GmbH, DE); Planscan (Planmeca, FIN); and laboratory scanning systems: s600 ARTI (Zirkonzahn GmbH, IT); Imetric Iscan D104, CH); D900 (3Shape A/S, DNK); Zfx Evolution (Zfx GmbH, DE) (each n=10). Reference-scanning was done by ATOS Core (GOM mbH, DE). The resulting digital impressions were superimposed with the master-scan. The measured deviations by points (trueness) for intraoral scanners were: True Definition - 15.0±2.85 μm (single tooth) and 45.0±19.11 µm (full arch); Trios - 17.1±1.44 and 58.8±27.36 µm; CEREC AC Bluecam - 22.3±5.58 and 20.3±4.13 µm; CEREC Omnicam - 25.0±1.06 and 78.5±27.03 µm; 3D Progress - 26.4±5.75 and 213.5±47.44 µm; Planscan - 54.6±11.58 and 205.2±21.73 µm. For laboratory scanners: Imetric Iscan D104 - 10.2±0.87 μm (stamp) and 65.3±5.36 µm (full arch); Zfx Evolution - 12.8±0.83 and 66.4±2.80 µm; Zirkonzahn s600 ARTI - 15.1±1.36 and 65.9±1.33 µm; 3Shape D900 - 19.9±0.53 and 63.6±0.83 µm. Precision was: True Definition - 19.9±2.77 μm (single tooth) and 40.1±11.04 µm (full arch); Trios - 25.8±2.49 and 69.9±18.95 µm; CEREC AC Bluecam - 36.4±2.78 and 46.6±3.44 µm; CEREC Omnicam - 37.6±3.29 and 76.2±13.36 µm; 3D Progress - 76.9±11.04 and 102.2±8.06 µm; Planscan - 74.3±6.58 and 93.9±15.32 µm. For laboratory scanners: Imetric Iscan D104 - 11.7±4.39 μm (stamp) and 31.2±5.58 µm (full arch); Zfx Evolution - 8.4±0.49 and 24.8±3.98 µm; Zirkonzahn s600 ARTI - 13.4±6.74 and 20.7±4.34 µm; 3Shape D900 - 10.4±0.93 and 17.8±0.62 µm. Whole deviation of the dental arch was: 3D Progress - 98.0±5.70 µm; True Definition - 47.1±9.61 µm; Trios - 59.6±18.77 µm; Omnicam - 77.8±8.79 µm; Planscan - 107.9±1.58 µm; Bluecam - 46.8±1.22 µm; Imetric - 36.4±1.62 µm; Zfx Evolution - 29.5±0.58 µm; S600 ARTI - 35.0±1.04 µm; 3Shape D900 - 32.7±0.29 µm. The results indicate that digital impressions provide enough accuracy for clinical application.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app