CLINICAL STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Accuracy and Trending Ability of the Fourth-Generation FloTrac/Vigileo System in Patients With Low Cardiac Index.

OBJECTIVES: To determine the accuracy and trending ability of the fourth-generation FloTrac/Vigileo in patients with low cardiac index by comparing FloTrac/Vigileo-derived cardiac index with that measured by 3-dimensional echocardiography.

DESIGN: Prospective clinical study.

SETTING: Cardiac surgery operating room in a single cardiovascular center.

PARTICIPANTS: Twenty-five patients undergoing elective cardiac resynchronization therapy lead implantation.

INTERVENTIONS: FloTrac/Vigileo-derived cardiac index and 3-dimensional echocardiography-derived cardiac index were determined simultaneously before and after phenylephrine bolus and cardiac resynchronization therapy using 3-dimensional echocardiography-derived cardiac index as the reference method.

MEASUREMENTS AND MAIN RESULTS: Cardiac index measured by the fourth-generation FloTrac/Vigileo had a wide limit of agreement with that measured by 3-dimensional echocardiography, with a percentage error of 59.1%. The tracking ability of the unit after both phenylephrine administration and cardiac resynchronization therapy were measured by concordance rate, and both were below the acceptable limit (72.7% and 85%, respectively).

CONCLUSIONS: The degree of accuracy of the fourth-generation FloTrac/Vigileo in patients with low cardiac index was not acceptable, and high systemic vascular resistance in patients with low cardiac index may have contributed to this inaccuracy. The tracking ability of the fourth-generation FloTrac/Vigileo after phenylephrine administration or cardiac resynchronization therapy was below acceptable limits.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app