BACKGROUND: Users of point-of-care testing (POCT) in Norway participate in a quality improvement system that includes education and guidance in safe laboratory management along with participation in external quality assurance schemes (EQAS).The aim of this study was to identify the effect on the analytical performance of POCT C-reactive protein (CRP), glucose, and hemoglobin (Hb) with the use of a quality improvement system over time and to identify which factors are associated with good performance.
METHODS: Participants' results from 19 EQAS for CRP, glucose, and Hb from 2006 to 2015 along with information on the instruments used and different practice characteristics were analyzed. Logistic regression analysis was used to evaluate the factors associated with good laboratory performance. An instrument evaluation and comparison for CRP determination was performed by using commutable EQA material.
RESULTS: The mean number of participants in each EQAS was 2134, 2357, and 2271 for CRP, glucose, and Hb, respectively. The percentage of good participant performances increased gradually whereas that of poor performances decreased with participation in a quality improvement system over 9 years for all 3 analytes. Independent factors associated with good performance were type of instrument, the number of times performing EQA, performing internal QC weekly, performing 10 or more tests weekly, and having laboratory-qualified personnel perform the tests. Considering CRP instrument performance, Afinion and QuikRead exhibited the lowest systematic deviation.
CONCLUSIONS: The analytical quality of CRP, glucose, and Hb testing is improved by systematic participation in a quality improvement system over time.
METHODS: Participants' results from 19 EQAS for CRP, glucose, and Hb from 2006 to 2015 along with information on the instruments used and different practice characteristics were analyzed. Logistic regression analysis was used to evaluate the factors associated with good laboratory performance. An instrument evaluation and comparison for CRP determination was performed by using commutable EQA material.
RESULTS: The mean number of participants in each EQAS was 2134, 2357, and 2271 for CRP, glucose, and Hb, respectively. The percentage of good participant performances increased gradually whereas that of poor performances decreased with participation in a quality improvement system over 9 years for all 3 analytes. Independent factors associated with good performance were type of instrument, the number of times performing EQA, performing internal QC weekly, performing 10 or more tests weekly, and having laboratory-qualified personnel perform the tests. Considering CRP instrument performance, Afinion and QuikRead exhibited the lowest systematic deviation.
CONCLUSIONS: The analytical quality of CRP, glucose, and Hb testing is improved by systematic participation in a quality improvement system over time.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app