Micro-RNA-21 (biomarker) and global longitudinal strain (functional marker) in detection of myocardial fibrotic burden in severe aortic valve stenosis: a pilot study.
Journal of Translational Medicine 2016 August 28
AIMS: Myocardial fibrosis (MF) is a deleterious consequence of aortic valve stenosis (AVS). Global longitudinal strain (GLS) is a novel left ventricular (LV) functional parameter potentially useful to non-invasively estimate MF. MicroRNAs (miRNAs) are non-coding small ribonucleic acids (RNA) modulating genes function, mainly through RNA degradation. miRNA-21 is a biomarker associated with MF in pressure overload. The aim of the present study was to find an integrated algorithm for detection of MF using a combined approach with both bio- and functional markers.
METHODS: Thirty-six patients (75.2 ± 8 y.o.; 63 % Female) with severe AVS and preserved LV ejection fraction (EF), candidate to surgical aortic valve replacement (sAVR) were enrolled. Clinical, bio-humoral evaluation (including plasmatic miRNA-21 collected using specific tubes, PAXgene, for stabilization of peripheral RNA) and a complete echocardiographic study, including GLS and septal strain, were performed before sAVR. Twenty-eight of those patients underwent sAVR and, in 23 of them, an inter-ventricular septum biopsy was performed. Tissues were fixed in formalin and embedded in paraffin. Sections were stained with Hematoxylin and Eosin for histological evaluation and with histochemical Masson trichrome for collagen fibers. The different components were calculated and expressed as micrometers(2). To evaluate tissue miRNA components, sections 2-μm thick were cut using a microtome blade for each slide. Regression analysis was performed to test association between dependent variable and various predictors included in the model.
RESULTS: Despite a preserved EF (66 ± 11 %), patients presented altered myocardial deformation parameters (GLS -14,02 ± 3.8 %; septal longitudinal strain, SSL -9.63 ± 2.9 %; septal longitudinal strain rate, SL-Sr -0.58 ± 0.17 1/s; Septal Longitudinal early-diastolic strain rate, SL-SrE 0.62 ± 0.32 1/s). The extent of MF showed an inverse association with both GLS and septal longitudinal deformation indices (GLS: R(2) = 0.30; p = 0.02; SSL: R(2) = 0.36; p = 0.01; SL-Sr: R(2) = 0.39; p < 0.001; SL-SrE: R(2) = 0.35; p = 0.001). miRNA-21 was mainly expressed in fibrous tissue (p < 0.0001). A significant association between MF and plasmatic miRNA-21, alone and weighted for measures of structural (LVMi R(2) = 0.50; p = 0.0005) and functional (SSL R(2) = 0.35; p = 0.006) remodeling, was found.
CONCLUSIONS: In AVS, MF is associated with alterations of regional and global strain. Plasmatic miRNA-21 is directly related to MF and associated with LV structural and functional impairment.
METHODS: Thirty-six patients (75.2 ± 8 y.o.; 63 % Female) with severe AVS and preserved LV ejection fraction (EF), candidate to surgical aortic valve replacement (sAVR) were enrolled. Clinical, bio-humoral evaluation (including plasmatic miRNA-21 collected using specific tubes, PAXgene, for stabilization of peripheral RNA) and a complete echocardiographic study, including GLS and septal strain, were performed before sAVR. Twenty-eight of those patients underwent sAVR and, in 23 of them, an inter-ventricular septum biopsy was performed. Tissues were fixed in formalin and embedded in paraffin. Sections were stained with Hematoxylin and Eosin for histological evaluation and with histochemical Masson trichrome for collagen fibers. The different components were calculated and expressed as micrometers(2). To evaluate tissue miRNA components, sections 2-μm thick were cut using a microtome blade for each slide. Regression analysis was performed to test association between dependent variable and various predictors included in the model.
RESULTS: Despite a preserved EF (66 ± 11 %), patients presented altered myocardial deformation parameters (GLS -14,02 ± 3.8 %; septal longitudinal strain, SSL -9.63 ± 2.9 %; septal longitudinal strain rate, SL-Sr -0.58 ± 0.17 1/s; Septal Longitudinal early-diastolic strain rate, SL-SrE 0.62 ± 0.32 1/s). The extent of MF showed an inverse association with both GLS and septal longitudinal deformation indices (GLS: R(2) = 0.30; p = 0.02; SSL: R(2) = 0.36; p = 0.01; SL-Sr: R(2) = 0.39; p < 0.001; SL-SrE: R(2) = 0.35; p = 0.001). miRNA-21 was mainly expressed in fibrous tissue (p < 0.0001). A significant association between MF and plasmatic miRNA-21, alone and weighted for measures of structural (LVMi R(2) = 0.50; p = 0.0005) and functional (SSL R(2) = 0.35; p = 0.006) remodeling, was found.
CONCLUSIONS: In AVS, MF is associated with alterations of regional and global strain. Plasmatic miRNA-21 is directly related to MF and associated with LV structural and functional impairment.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app