Add like
Add dislike
Add to saved papers

Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations.

STUDY DESIGN: Retrospective.

PURPOSE: This study aims to investigate the accuracy of the oblique fluoroscopic view, based on preoperative computed tomography (CT) images for accurate placement of lumbosacral percutaneous pedicle screws (PPS).

OVERVIEW OF LITERATURE: Although PPS misplacement has been reported as one of the main complications in minimally invasive spine surgery, there is no comparative data on the misplacement rate among different fluoroscopic techniques, or comparing such techniques with open procedures.

METHODS: We retrospectively selected 230 consecutive patients who underwent posterior spinal fusion with a pedicle screw construct for degenerative lumbar disease, and divided them into 3 groups, those who had undergone: minimally invasive percutaneous procedure using biplane (lateral and anterior-posterior views using a single C-arm) fluoroscope views (group M-1), minimally invasive percutaneous procedure using the oblique fluoroscopic view based on preoperative CT (group M-2), and conventional open procedure using a lateral fluoroscopic view (group O: controls). The relative position of the screw to the pedicle was graded for the pedicle breach as no breach, <2 mm, 2-4 mm, or >4 mm. Inaccuracy was calculated and assessed according to the spinal level, direction and neurological deficit. Inter-group radiation exposure was estimated using fluoroscopy time.

RESULTS: Inaccuracy involved an incline toward L5, causing medial or lateral perforation of pedicles in group M-1, but it was distributed relatively equally throughout multiple levels in groups M-2 and controls. The mean fluoroscopy time/case ranged from 1.6 to 3.9 minutes.

CONCLUSIONS: Minimally invasive lumbosacral PPS placement using the conventional fluoroscopic technique carries an increased risk of inaccurate screw placement and resultant neurological deficits, compared with that of the open procedure. Inaccuracy tended to be distributed between medial and lateral perforations of the L5 pedicle, as a result of pedicle morphology and the PPS pathway. Oblique fluoroscopic views, based on CT measurement, may allow accurate PPS insertion with a shorter fluoroscopy time.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app