We have located links that may give you full text access.
Validation of a novel real-time PCR assay for detection of HLA-B*15:02 allele for prevention of carbamazepine - Induced Stevens-Johnson syndrome/Toxic Epidermal Necrolysis in individuals of Asian ancestry.
Human Immunology 2016 December
OBJECTIVES: Screening for the HLA-B*15:02 allele has been recommended to prevent carbamazepine (CBZ) - induced Stevens-Johnson syndrome (SJS) and Toxic Epidermal Necrolysis (TEN) in individuals with Asian ancestry. We aimed, therefore, to develop and validate a robust and inexpensive method for detection of the HLA-B*15:02 allele.
METHODS: Real-time PCR using TaqMan® probes followed by SYBR® Green was used to detect the HLA-B*15:02 allele prior to treatment with CBZ therapy.
RESULTS: A total of 121 samples were tested. The assay has a sensitivity of 100% (95% CI: 76.84-100.0%), a specificity of 100% (95% CI: 96.61-100%), a positive predictive value of 100% (95% CI: 76.84-100%) and a negative predictive value of 100.0% (95% CI: 96.61-100.0%), respectively. There was 100% agreement between our results and genotyping using Luminex SSO/SBT/SSP. The lowest limit of detection of the TaqMan® probe is 0.05ng/μl and the SYBR® Green is 0.5ng/μl of DNA. The unit cost of using the TaqMan® probe followed by SYBR® Green is only $4.7 USD.
CONCLUSION: We developed a novel assay for the detection of the HLA-B*15:02 allele, which is robust, inexpensive and suitable for screening individuals of Asian ancestry in the prevention of CBZ-induced SJS/TEN.
METHODS: Real-time PCR using TaqMan® probes followed by SYBR® Green was used to detect the HLA-B*15:02 allele prior to treatment with CBZ therapy.
RESULTS: A total of 121 samples were tested. The assay has a sensitivity of 100% (95% CI: 76.84-100.0%), a specificity of 100% (95% CI: 96.61-100%), a positive predictive value of 100% (95% CI: 76.84-100%) and a negative predictive value of 100.0% (95% CI: 96.61-100.0%), respectively. There was 100% agreement between our results and genotyping using Luminex SSO/SBT/SSP. The lowest limit of detection of the TaqMan® probe is 0.05ng/μl and the SYBR® Green is 0.5ng/μl of DNA. The unit cost of using the TaqMan® probe followed by SYBR® Green is only $4.7 USD.
CONCLUSION: We developed a novel assay for the detection of the HLA-B*15:02 allele, which is robust, inexpensive and suitable for screening individuals of Asian ancestry in the prevention of CBZ-induced SJS/TEN.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app