Add like
Add dislike
Add to saved papers

Innovative combination of QuEChERS extraction with on-line solid-phase extract purification and pre-concentration, followed by liquid chromatography-tandem mass spectrometry for the determination of non-steroidal anti-inflammatory drugs and their metabolites in sewage sludge.

Analytica Chimica Acta 2016 September 8
For the first time QuEChERS extraction of sewage sludge was combined with the automatic solid-phase pre-concentration and purification of the extract (following indicated as SPE) and LC-MS/MS analysis, for the determination of the non-steroidal anti-inflammatory drugs acetylsalicylic acid (ASA), diclofenac (DIC), fenbufen (FEN), flurbiprofen (FLU), ketoprofen (KET), ibuprofen (IBU) and naproxen (NAP), and their metabolites salicylic acid (SAL), 4'-hydroxydiclofenac (4'-HYDIC), 1-hydroxyibuprofen (1-HYIBU), 2-hydroxyibuprofen (2-HYIBU), 3-hydroxyibuprofen (3-HYIBU) and o-desmethylnaproxen (O-DMNAP). Various commercial pellicular stationary phases (i.e. silica gel functionalized with octadecyl, biphenyl, phenylhexyl and pentafluorophenyl groups) were preliminarily investigated for the resolution of target analytes and different sorbent phases (i.e. octyl or octadecyl functionalized silica gel and a polymeric phase functionalized with N-benzylpyrrolidone groups) were tested for the SPE phase. The optimized method involves the QuEChERS extraction of 1 g of freeze-dried sludge with 15 mL of water/acetonitrile 1/2 (v/v), the SPE of the extract with the N-benzylpyrrolidone polymeric phase and the water/acetonitrile gradient elution on the pentafluorophenyl stationary phase at room temperature. Matrix effect was always suppressive and in most cases low, being it ≤20% for ASA, DIC, FLU, KET, IBU, 1-HYIBU, 2-HYIBU, 3-HYIBU, NAP and O-DMNAP, and included in the range of 35-47% for the other analytes. Recoveries were evaluated at three spiking levels, evidencing almost quantitative values for HYIBUs and O-DMNAP; for ASA, SAL and KET the recoveries were included in between 50 and 76%, whereas for the other compounds they ranged from 36% to 55%. The proposed method showed better analytical performances than those so far published, being suitable for target compound determination in real samples from tens of pg g(-1) to ng g(-1) of freeze-dried sludge, with a total analysis time of 30 min per sample.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app