The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure.
Cardiovascular Ultrasound 2016 August 21
BACKGROUND: Central venous pressure (CVP) and right atrial pressure (RAP) are important parameters in the complete hemodynamic assessment of a patient. Sonographic measurement of the inferior vena cava (IVC) diameter is a non-invasive method of estimating these parameters, but there are limited data summarizing its diagnostic accuracy across multiple studies. We performed a comprehensive review of the existing literature to examine the diagnostic accuracy and clinical utility of sonographic measurement of IVC diameter as a method for assessing CVP and RAP.
METHODS: We performed a systematic search using PubMed of clinical studies comparing sonographic evaluation of IVC diameter and collapsibility against gold standard measurements of CVP and RAP. We included clinical studies that were performed in adults, used current imaging techniques, and were published in English.
RESULTS: Twenty one clinical studies were identified that compared sonographic assessment of IVC diameter with CVP and RAP and met all inclusion criteria. Despite substantial heterogeneity in measurement techniques and patient populations, most studies demonstrated moderate strength correlations between measurements of IVC diameter and collapsibility and CVP or RAP, but more favorable diagnostic accuracy using pre-specified cut points. Findings were inconsistent among mechanically ventilated patients, except in the absence of positive end-expiratory pressure.
CONCLUSION: Sonographic measurement of IVC diameter and collapsibility is a valid method of estimating CVP and RAP. Given the ease, safety, and availability of this non-invasive technique, broader adoption and application of this method in clinical settings is warranted.
METHODS: We performed a systematic search using PubMed of clinical studies comparing sonographic evaluation of IVC diameter and collapsibility against gold standard measurements of CVP and RAP. We included clinical studies that were performed in adults, used current imaging techniques, and were published in English.
RESULTS: Twenty one clinical studies were identified that compared sonographic assessment of IVC diameter with CVP and RAP and met all inclusion criteria. Despite substantial heterogeneity in measurement techniques and patient populations, most studies demonstrated moderate strength correlations between measurements of IVC diameter and collapsibility and CVP or RAP, but more favorable diagnostic accuracy using pre-specified cut points. Findings were inconsistent among mechanically ventilated patients, except in the absence of positive end-expiratory pressure.
CONCLUSION: Sonographic measurement of IVC diameter and collapsibility is a valid method of estimating CVP and RAP. Given the ease, safety, and availability of this non-invasive technique, broader adoption and application of this method in clinical settings is warranted.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app