We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Prospective head motion correction using FID-guided on-demand image navigators.
Magnetic Resonance in Medicine 2017 July
PURPOSE: We suggest a motion correction concept that employs free-induction-decay (FID) navigator signals to continuously monitor motion and to guide the acquisition of image navigators for prospective motion correction following motion detection.
METHODS: Motion causes out-of-range signal changes in FID time series that, and in this approach, initiate the acquisition of an image navigator. Co-registration of the image navigator to a reference provides rigid-body-motion parameters to facilitate prospective motion correction. Both FID and image navigator are integrated into a prototype magnetization-prepared rapid gradient-echo (MPRAGE) sequence. The performance of the method is investigated using image quality metrics and the consistency of brain volume measurements.
RESULTS: Ten healthy subjects were scanned (a) while performing head movements (nodding, shaking, and moving in z-direction) and (b) to assess the co-registration performance. Mean absolute errors of 0.27 ± 0.38 mm and 0.19 ± 0.24° for translation and rotation parameters were measured. Image quality was qualitatively improved after correction. Significant improvements were observed in automated image quality measures and for most quantitative brain volume computations after correction.
CONCLUSION: The presented method provides high sensitivity to detect head motion while minimizing the time invested in acquiring navigator images. Limits of this implementation arise from temporal resolution to detect motion, false-positive alarms, and registration accuracy. Magn Reson Med 78:193-203, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
METHODS: Motion causes out-of-range signal changes in FID time series that, and in this approach, initiate the acquisition of an image navigator. Co-registration of the image navigator to a reference provides rigid-body-motion parameters to facilitate prospective motion correction. Both FID and image navigator are integrated into a prototype magnetization-prepared rapid gradient-echo (MPRAGE) sequence. The performance of the method is investigated using image quality metrics and the consistency of brain volume measurements.
RESULTS: Ten healthy subjects were scanned (a) while performing head movements (nodding, shaking, and moving in z-direction) and (b) to assess the co-registration performance. Mean absolute errors of 0.27 ± 0.38 mm and 0.19 ± 0.24° for translation and rotation parameters were measured. Image quality was qualitatively improved after correction. Significant improvements were observed in automated image quality measures and for most quantitative brain volume computations after correction.
CONCLUSION: The presented method provides high sensitivity to detect head motion while minimizing the time invested in acquiring navigator images. Limits of this implementation arise from temporal resolution to detect motion, false-positive alarms, and registration accuracy. Magn Reson Med 78:193-203, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app