Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Triple-Quadrupole Inductively Coupled Plasma-Mass Spectrometry with a High-Efficiency Sample Introduction System for Ultratrace Determination of (135)Cs and (137)Cs in Environmental Samples at Femtogram Levels.

Analytical Chemistry 2016 September 7
High yield fission products, (135)Cs and (137)Cs, have entered the environment as a result of anthropogenic nuclear activities. Analytical methods for ultratrace measurement of (135)Cs and (137)Cs are required for environmental geochemical and nuclear forensics studies. Here we report a highly sensitive method combining a desolvation sample introduction system (APEX-Q) with triple-quadrupole inductively coupled plasma mass spectrometry (AEPX-ICPMS/MS) for the determination of (135)Cs and (135)Cs/(137)Cs isotope ratio at femtogram levels. Using this system, we introduced only selected ions into the collision/reaction cell to react with N2O, significantly reducing the isobaric interferences ((135)Ba(+) and (137)Ba(+)) and polyatomic interferences ((95,97)Mo(40)Ar(+), (119)Sn(16)O(+), and (121)Sb(16)O(+)). Compared to the instrument setup of ICPMS/MS, the APEX-ICPMS/MS enables a 10-fold sensitivity increase. In addition, an effective chemical separation scheme consisting of ammonium molybdophosphate (AMP) Cs-selective adsorption and two-stage ion-exchange chromatographic separation was developed to remove major matrix and interfering elements from environmental samples (10-40 g). This separation method showed high decontamination factors (10(4)-10(7)) for major matrix elements (Al, Ca, K, Mg, Na, and Si) and interfering elements (Ba, Mo, Sb, and Sn). The high sensitivity of APEX-ICPMS/MS and the effective removal sample matrix allowed reliable analysis of (135)Cs and (137)Cs with extremely low detection limits (0.002 pg mL(-1), corresponding to 0.006 Bq mL(-1) (137)Cs). The accuracy and applicability of the APEX-ICPMS/MS method was validated by analysis of seven standard reference materials (soils, sediment, and plants). For the first time, ultratrace determination of (135)Cs and (135)Cs/(137)Cs isotope ratio at global fallout source environmental samples was achieved with the ICPMS technique.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app