Five-year clinical performance of a biodegradable polymer-coated biolimus-eluting stent in unselected patients.
Heart 2017 January 16
OBJECTIVE: To evaluate the long-term follow-up of the unrestricted use of a biodegradable polymer-coated drug-eluting stent in patients undergoing percutaneous coronary intervention (PCI).
METHODS: The Nobori 2 study was a prospective, multicentre, observational registry evaluating the safety and the efficacy of the biodegradable polymer biolimus-eluting stent (BP-BES) among 3067 patients recruited at 125 international sites. The primary combined endpoint was a composite of cardiac death, myocardial infarction and target-lesion revascularisation (TLR).
RESULTS: Five-year follow-up was available in 2738 (89.3%) patients. The combined endpoint occurred in 268 patients (10%, 95% CIs 8.9% to 11.3%) at 5 years, with 3.9% of events during the first year and 6.2% during years 1-5 of follow-up. Cumulative rates of TLR and definite/probable stent thrombosis were 5.3% (95% CI 4.5% to 6.3%) and 1.1% (95% CI 0.8% to 1.6%), respectively. Between 1 and 5 years, TLR and very late stent thrombosis rates were 3.5% (95% CI 2.8% to 4.4%) and 0.6% (95% CI 0.3% to 1.1%), respectively. Previous PCI (HR, 2.05, 95% CI 1.68 to 2.50), moderate-to-severe renal disease (HR, 1.89, 95% CI 1.30 to 2.74) and peripheral vascular disease (HR, 1.86, 95% CI 1.38 to 2.52) were the three most powerful independent predictors of the combined endpoint at 5 years.
CONCLUSIONS: The final 5-year follow-up of the Nobori 2 registry demonstrates the safety and effectiveness of the BP-BES in an unselected, broadly inclusive cohort of PCI patients, highlighting the excellent performance of this coronary stent technology after polymer biodegradation.
TRIAL REGISTRATION NUMBER: ISRCTN81649913; Results.
METHODS: The Nobori 2 study was a prospective, multicentre, observational registry evaluating the safety and the efficacy of the biodegradable polymer biolimus-eluting stent (BP-BES) among 3067 patients recruited at 125 international sites. The primary combined endpoint was a composite of cardiac death, myocardial infarction and target-lesion revascularisation (TLR).
RESULTS: Five-year follow-up was available in 2738 (89.3%) patients. The combined endpoint occurred in 268 patients (10%, 95% CIs 8.9% to 11.3%) at 5 years, with 3.9% of events during the first year and 6.2% during years 1-5 of follow-up. Cumulative rates of TLR and definite/probable stent thrombosis were 5.3% (95% CI 4.5% to 6.3%) and 1.1% (95% CI 0.8% to 1.6%), respectively. Between 1 and 5 years, TLR and very late stent thrombosis rates were 3.5% (95% CI 2.8% to 4.4%) and 0.6% (95% CI 0.3% to 1.1%), respectively. Previous PCI (HR, 2.05, 95% CI 1.68 to 2.50), moderate-to-severe renal disease (HR, 1.89, 95% CI 1.30 to 2.74) and peripheral vascular disease (HR, 1.86, 95% CI 1.38 to 2.52) were the three most powerful independent predictors of the combined endpoint at 5 years.
CONCLUSIONS: The final 5-year follow-up of the Nobori 2 registry demonstrates the safety and effectiveness of the BP-BES in an unselected, broadly inclusive cohort of PCI patients, highlighting the excellent performance of this coronary stent technology after polymer biodegradation.
TRIAL REGISTRATION NUMBER: ISRCTN81649913; Results.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app