Long endomedullary nail in proximal third humeral shaft fractures.

Injury 2016 October
INTRODUCTION: Proximal humeral fractures with a spiral line of fracture extending from the humeral head to the diaphyseal region are increasing. Treatment for these fractures is comparable to that for shaft fractures. The purpose of this study was to evaluate the use of a new "Long" humeral nail for this type of lesion and identify the best distal locking.

MATERIALS AND METHODS: Forty-three patients treated with a Long Diphos Nail® were selected for this study: main exclusion criteria were poor cognitive and responsive ability to physical therapy, four-part fracture requiring humeral head replacement, an isolated greater or lesser tubercle fracture and a head-splitting fracture. All patients were divided into two groups according to the distal locking (single or double) and clinically evaluated at 1, 3, 6 and 12 months after surgery. The following parameters were evaluated: fracture healing on radiographic images every month; level of pain with Visual Analogue Scale (VAS); recovery of shoulder function or ability to resume normal daily activities according to the Constant Scoring System (CSS); patient satisfaction; and complications, like fracture consolidation defect or delay. A statistical analysis was performed.

RESULTS: Improvements in pain, satisfaction and shoulder functional recovery were recorded. Patients reached fracture healing in two to six months. The mean healing time was better for double distal locking (p=0.04).There was a clinically greater difference (p=0.006) between the groups for the mean Constant score at 3 months follow-up, with better results for the double distal locking group. Complications were: one patient with a consolidation delay with a single distal locking screw breakage; it was necessary to remove the nail and perform a second treatment.

CONCLUSIONS: The results of the study indicate the efficacy of Long Diphos Nail® in the treatment of fractures with a line of fracture extending to the proximal diaphyseal region. The features of a multiplane stabilisation above the fracture and a distal double locking may represent the key for a good fixation for 11-A2, A3 or B2 fractures with a long spiral line. A double distal locking reduces fracture micro-instability and so patients recover function and strength quicker because of less pain at the fracture site.

STUDY DESIGN: retrospective, cohort of cases.

LEVEL OF EVIDENCE: IV.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app