Hand-held dynamometry strength measures for internal and external rotation demonstrate superior reliability, lower minimal detectable change and higher correlation to isokinetic dynamometry than externally-fixed dynamometry of the shoulder.
Physical Therapy in Sport 2016 September
OBJECTIVES: To investigate inter and intra-rater reliability of hand held (HHD) and externally fixed (EFD) dynamometry for shoulder internal (IR) and external rotation (ER) strength and their correlation to isokinetic testing.
DESIGN: Within participant, inter and intra-rater reliability study.
PARTICIPANTS: Twenty active, healthy male and female participants underwent testing by two examiners.
OUTCOME MEASURES: Intra-class coefficients (ICC), percentage standard error of measurement (%SEM), and percentage minimal detectable change (%MDC) were calculated for inter-rater, intra-day and intra-rater, inter-week reliability. Maximum and average of three repetitions were compared to the isokinetic results at three speeds (60°/sec, 180°/sec, 240°/sec) for both concentric and eccentric contractions.
RESULTS: Inter and intra-tester values demonstrated good to high agreement (HHD, ICC range = 0.89-0.97, %SEM = 4.80-8.60%, %MDC = 13.29-23.70%; EFD, ICC = 0.88-0.96, %SEM = 6.60-11.00%, %MDC = 18.40-30.04%). HHD and EFD showed moderate to very strong correlations to the isokinetic testing (HHD, r = 0.45-0.86; EFD, r = 0.49-0.83).
CONCLUSIONS: The results of this study indicate that both EFD and HHD are suitable for clinical practice and research. Hand-held dynamometry is preferred due to its higher intra- and inter-rater reliability and smaller MDC and lower SEM.
DESIGN: Within participant, inter and intra-rater reliability study.
PARTICIPANTS: Twenty active, healthy male and female participants underwent testing by two examiners.
OUTCOME MEASURES: Intra-class coefficients (ICC), percentage standard error of measurement (%SEM), and percentage minimal detectable change (%MDC) were calculated for inter-rater, intra-day and intra-rater, inter-week reliability. Maximum and average of three repetitions were compared to the isokinetic results at three speeds (60°/sec, 180°/sec, 240°/sec) for both concentric and eccentric contractions.
RESULTS: Inter and intra-tester values demonstrated good to high agreement (HHD, ICC range = 0.89-0.97, %SEM = 4.80-8.60%, %MDC = 13.29-23.70%; EFD, ICC = 0.88-0.96, %SEM = 6.60-11.00%, %MDC = 18.40-30.04%). HHD and EFD showed moderate to very strong correlations to the isokinetic testing (HHD, r = 0.45-0.86; EFD, r = 0.49-0.83).
CONCLUSIONS: The results of this study indicate that both EFD and HHD are suitable for clinical practice and research. Hand-held dynamometry is preferred due to its higher intra- and inter-rater reliability and smaller MDC and lower SEM.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app