Impact of the high-frequency cutoff of bandpass filtering on ECG quality and clinical interpretation: A comparison between 40Hz and 150Hz cutoff in a surgical preoperative adult outpatient population.

BACKGROUND: In 1990 the American Heart Association (AHA) established a standard 0.05 to 150Hz bandwidth for the routine recording of 12-lead electrocardiograms (ECGs). However, subsequent studies have indicated a very high prevalence of deviations from the recommended cutoffs.

OBJECTIVE: This prospective observational study investigates the impact of 40Hz compared to 150Hz high-frequency cutoffs on ECG quality and clinical interpretation in a single-center surgical outpatient population.

METHODS: 1582 consecutive adult patients underwent two standard 12-lead ECG tracings using different high-frequency cutoffs (40Hz and 150Hz). Two blinded cardiologists randomly reviewed and interpreted the recordings according to pre-defined parameters (PR and ST segment, Q and T wave abnormalities). An arbitrary score, ranging from 1 to 3, was established to evaluate the perceived quality of the recordings and the non-interpretable ECGs were noted. The tracings were then matched to compare interpretations between 40 and 150Hz filters.

RESULTS: A 40Hz high-frequency cutoff resulted in an increased rate of optimal quality ECGs compared to the 150Hz cutoff (93.4% vs 54.6%; p<0.001) and a lower rate of non-interpretable traces (0.25% vs 4.80%; p<0.001). Analyzing the morphologic parameters, no significant differences between the filter settings were found, except for a higher incidence of the J-point elevation in the 40Hz high-frequency cutoff (p=0.007) and a higher incidence of left ventricular hypertrophy in the 150Hz high-frequency cutoff (7.4% vs 5.4%, p<0.001). The latter was noted only in ECGs with borderline QRS amplitudes (between 3.3 and 3.7mV; p<0.001).

CONCLUSION: Despite current recommendations, the large deviation from standard high-frequency cutoff in clinical practice does not seem to significantly affect ECG clinical interpretation and a 40Hz high-frequency cutoff of the band-pass filtering may be acceptable in a low risk population, allowing for a better quality of tracings.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app