Eliminating guidewire retention during ultrasound guided central venous catheter insertion via an educational program, a modified CVC set, and a drape with reminder stickers.
Guidewire retention is a severe but preventable complication from central venous catheter (CVC) insertion. There were three cases of guidewire retention during CVC insertion in the medical intensive care unit (MICU) in Singapore General Hospital, in the period between December 2011 and February 2012. The primary objective of this quality improvement project was to eliminate future incidences of guidewire retention during CVC insertion in the MICU and medical intermediate care area (MICA) via a structured educational program and a cost effective modified CVC set. The secondary objective was to perform a cost analysis and comparison between the use of the conventional hospital CVC set and drape with our newly modified CVC dressing kit. Root cause analysis of the three cases identified major factors leading to guidewire retention. Interventions were planned and tested using PDSA cycles. Internal medicine trainees rotating through MICU and MICA during the period between February 2012 and June 2013 underwent a multi-modal structured CVC insertion training program with hands on simulation. They also used a newly modified CVC dressing kit and drape. The CVC dressing kit was modified (CVC PLUS) to include a sterile drape with reminder stickers stating "REMOVE the GUIDEWIRE," as well as a sterile ultrasound sleeve. The total number of CVC insertions performed and guidewire retentions were monitored. During the period of study there were 320 CVC insertions in the MICU and MICA. Since this quality improvement project was initiated, and up to the submission of this article, there have not been any further cases of guidewire retention in the MICU and MICA. The total cost reduction per use of CVC PLUS was S$29.26 (Singaporean Dollars). A multi-modal structured training program, integrated with a modified, pre-packed CVC set, and drapes with reminder stickers (all included in CVC PLUS) were cost effective, and improved patient safety by eliminating guidewire retention during CVC insertion.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app