We have located links that may give you full text access.
Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.
General Thoracic and Cardiovascular Surgery 2016 December
OBJECTIVE: We sought to compare the outcomes of Carpentier-Edwards PERIMOUNT (CEP), Magna and Magna Ease valves in Japanese elderly patients with severe aortic valve stenosis (AS).
METHODS: We retrospectively identified 136 patients (mean age 76.61 ± 5.5 years old) who had undergone isolated surgical aortic valve replacement (SAVR) using CEP, Magna, and Magna Ease valves at a single institution, from January 2001 to December 2013. We compared the valves according to their survival rates, freedom from major adverse cardiovascular and cerebrovascular events (MACCE), and durability and hemodynamic performance by echocardiographic data.
RESULTS: The thirty-day mortality after isolated SAVR in all the valve groups was "zero". The differences among the three groups in terms of survival rates, freedom from MACCE at 2 years, durability and hemodynamic performance of the valves by echocardiographic data was not statistically significant.
CONCLUSION: All CEP, Magna and Magna Ease valves seemed to be similarly useful in Japanese elderly patients with severe AS. Our data did not clearly support the superiority of one valve over another. A longer follow-up period might be necessary to compare the durability and hemodynamic performance of these valves with more certainty.
METHODS: We retrospectively identified 136 patients (mean age 76.61 ± 5.5 years old) who had undergone isolated surgical aortic valve replacement (SAVR) using CEP, Magna, and Magna Ease valves at a single institution, from January 2001 to December 2013. We compared the valves according to their survival rates, freedom from major adverse cardiovascular and cerebrovascular events (MACCE), and durability and hemodynamic performance by echocardiographic data.
RESULTS: The thirty-day mortality after isolated SAVR in all the valve groups was "zero". The differences among the three groups in terms of survival rates, freedom from MACCE at 2 years, durability and hemodynamic performance of the valves by echocardiographic data was not statistically significant.
CONCLUSION: All CEP, Magna and Magna Ease valves seemed to be similarly useful in Japanese elderly patients with severe AS. Our data did not clearly support the superiority of one valve over another. A longer follow-up period might be necessary to compare the durability and hemodynamic performance of these valves with more certainty.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app