Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

Effect of sensor location in dogs on performance of an interstitial glucose monitor.

OBJECTIVE To identify variations in glucose values concurrently obtained by use of a continuous glucose monitoring system (CGMS) at the same site, reliability of results for each site, lag time for each site, and influence of site thickness on CGMS accuracy. ANIMALS 8 random-source research dogs. PROCEDURES In experiment 1, 8 CGMS sensors were implanted bilaterally at 1 site (4 sensors/side) in 4 dogs. In experiment 2, 2 CGMS sensors were implanted bilaterally at each of 4 sites (1 sensor/side) in 8 dogs; 4 of those 8 dogs then were subjected to a glycemic clamp technique. The CGMS results were compared among sensors and with criterion-referenced results during periods of euglycemia for all 8 dogs and during hyperglycemia and hypoglycemia for 4 dogs during the glycemic clamp procedure. RESULTS Differences (median, -7 mg/dL; interquartile range [IQR], -18.75 to 3 mg/dL) between CGMS and criterion-referenced glucose concentrations differed significantly among dogs and sites; during euglycemia, they were not different from the expected normal variation between multiple sensors concurrently implanted at the same site. Differences (median, -35 mg/dL; IQR, -74 to -15 mg/dL) between CGMS and criterion-referenced concentrations were greater during changes in glucose concentrations. Thoracic sensors were most accurate but had the shortest mean functional life. CONCLUSIONS AND CLINICAL RELEVANCE Significant differences were detected between CGMS and criterion-referenced glucose concentrations. Overall clinical utility of CGMS was acceptable at all sites, with most of the values from all sensors, sites, and dogs meeting guidelines for point-of-care glucometers.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app