Journal Article
Research Support, N.I.H., Extramural
Add like
Add dislike
Add to saved papers

Chemical exchange saturation transfer of the cervical spinal cord at 7 T.

NMR in Biomedicine 2016 September
High-magnetic-field (7 T) chemical exchange saturation transfer (CEST) MRI provides information on the tissue biochemical environment. Multiple sclerosis (MS) affects the entire central nervous system, including the spinal cord. Optimal CEST saturation parameters found via simulation were implemented for CEST MRI in 10 healthy controls and 10 patients with MS, and the results were examined using traditional asymmetry analysis and a Lorentzian fitting method. In addition, T1 - and T2 *-weighted images were acquired for lesion localization and the transmitted B1 (+) field was evaluated to guide imaging parameters. Distinct spectral features for all tissue types studied were found both up- and downfield from the water resonance. The z spectra in healthy subjects had the expected z spectral shape with CEST effects apparent from 2.0 to 4.5 ppm. The z spectra from patients with MS demonstrated deviations from this expected normal shape, indicating this method's sensitivity to known pathology as well as to tissues appearing normal on conventional MRI. Examination of the calculated CESTasym revealed increased asymmetry around the amide proton resonance (Δω = 3.5 ppm), but it was apparent that this measure is complicated by detail in the CEST spectrum upfield from water, which is expected to result from the nuclear Overhauser effect. The z spectra upfield (negative ppm range) were also distinct between healthy and diseased tissue, and could not be ignored, particularly when considering the conventional asymmetry analysis used to quantify the CEST effect. For all frequencies greater than +1 ppm, the Lorentzian differences (and z spectra) for lesions and normal-appearing white matter were distinct from those for healthy white matter. The increased frequency separation and signal-to-noise ratio, in concert with prolonged T1 at 7 T, resulted in signal enhancements necessary to detect subtle tissue changes not possible at lower field strengths. This study presents CEST imaging metrics that may be sensitive to the extensive and temporally varying biochemical neuropathology of MS in the spinal cord. Copyright © 2016 John Wiley & Sons, Ltd.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app