Self-reported cochlear implant management skills: development and validation of the self-administered Cochlear Implant Management Skills (CIMS-self) survey.
Clinical Otolaryngology 2017 Februrary
OBJECTIVE: A self-administered device management survey was developed and validated to investigate the ability of cochlear implant recipients to self-report physical handling and care for their hearing implant device(s) and to identify factors that may influence self-reported management skills.
DESIGN: Survey development and validation. A prospective convenience cohort design study.
SETTING: Specialist hearing implant clinic.
PARTICIPANTS: Forty-nine post-lingually hearing impaired, adult cochlear implant recipients, at least 12 months postoperative.
MAIN OUTCOME MEASURES: Survey test-retest reliability, responsiveness, criterion validity and sensitivity and specificity compared to clinician evaluation of device management skills. Correlations between self-reported management skills and participant demographic, audiometric, cognitive function, clinical outcomes and device factors.
RESULTS: The self-administered Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (ICC = 0.884, P < 0.001; CI 95%: 0.721-0.952), responsiveness to intervention (management skills training) [t(20) = -3.245, P = 0.004], criterion validity (ICC = 0.765, P < 0.001; CI 95%: 0.584-0.868) and sensitivity (0.89). No associations were found between self-reported management skills and participant factors.
CONCLUSIONS: This study demonstrated that a self-report survey is an effective method for the evaluation of skills required for cochlear implant device management.
DESIGN: Survey development and validation. A prospective convenience cohort design study.
SETTING: Specialist hearing implant clinic.
PARTICIPANTS: Forty-nine post-lingually hearing impaired, adult cochlear implant recipients, at least 12 months postoperative.
MAIN OUTCOME MEASURES: Survey test-retest reliability, responsiveness, criterion validity and sensitivity and specificity compared to clinician evaluation of device management skills. Correlations between self-reported management skills and participant demographic, audiometric, cognitive function, clinical outcomes and device factors.
RESULTS: The self-administered Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (ICC = 0.884, P < 0.001; CI 95%: 0.721-0.952), responsiveness to intervention (management skills training) [t(20) = -3.245, P = 0.004], criterion validity (ICC = 0.765, P < 0.001; CI 95%: 0.584-0.868) and sensitivity (0.89). No associations were found between self-reported management skills and participant factors.
CONCLUSIONS: This study demonstrated that a self-report survey is an effective method for the evaluation of skills required for cochlear implant device management.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app