Establishment of national diagnostic reference levels for breast cancer CT protocols in radiation therapy.
British Journal of Radiology 2016 October
OBJECTIVE: To establish whether CT dose variation occurs in breast cancer localization procedures between radiation therapy (RT) centres in Ireland and to propose diagnostic reference levels (DRLs) for this procedure.
METHODS: All RT centres in Ireland were invited to participate in a dose audit survey, providing data on the CT dose index volume (CTDIvol), dose-length product (DLP), current-time product (mAs), tube potential, scan length, slice thickness, scanning margins, use of automated exposure control (AEC) and scanner technology for 10 patients with breast cancer who were average sized. DRLs were derived for each dose descriptor by calculation of the rounded 75th percentile of the distribution of mean doses.
RESULTS: Data were returned for 60 patients from 6 RT centres (50% response rate). Significant variation in mean CTDIvol and mean DLP was observed between centres (p < 0.0001). Mean scan lengths and mean mAs differed significantly between centres (p < 0.0001). Tube potential was 120 kV for all sequences across centres. AEC was employed in all but one centre. Proposed DRLs for breast localization are 26 mGy and 732 mGy cm for CTDIvol and DLP, respectively.
CONCLUSION: CT dose variation occurs between centres, establishing a need for optimization. DRLs for breast cancer localization have been proposed with the potential for reduction in CT dose.
ADVANCES IN KNOWLEDGE: This article provides the first reported DRL for breast cancer CT localization procedure in RT and can be used as a benchmark for comparison for other RT centres.
METHODS: All RT centres in Ireland were invited to participate in a dose audit survey, providing data on the CT dose index volume (CTDIvol), dose-length product (DLP), current-time product (mAs), tube potential, scan length, slice thickness, scanning margins, use of automated exposure control (AEC) and scanner technology for 10 patients with breast cancer who were average sized. DRLs were derived for each dose descriptor by calculation of the rounded 75th percentile of the distribution of mean doses.
RESULTS: Data were returned for 60 patients from 6 RT centres (50% response rate). Significant variation in mean CTDIvol and mean DLP was observed between centres (p < 0.0001). Mean scan lengths and mean mAs differed significantly between centres (p < 0.0001). Tube potential was 120 kV for all sequences across centres. AEC was employed in all but one centre. Proposed DRLs for breast localization are 26 mGy and 732 mGy cm for CTDIvol and DLP, respectively.
CONCLUSION: CT dose variation occurs between centres, establishing a need for optimization. DRLs for breast cancer localization have been proposed with the potential for reduction in CT dose.
ADVANCES IN KNOWLEDGE: This article provides the first reported DRL for breast cancer CT localization procedure in RT and can be used as a benchmark for comparison for other RT centres.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app