We have located links that may give you full text access.
Case Reports
Journal Article
Septic Pulmonary Embolism Caused by Infected Pacemaker Leads After Replacement of a Cardiac Resynchronization Therapy Device.
American Journal of Case Reports 2016 July 21
BACKGROUND Cardiac resynchronization therapy (CRT) has been demonstrated to reduce morbidity and mortality in patients with advanced, drug-refractory heart failure. Procedure-related mortality is less than 1% in larger studies. Approximately10% of CRT patients have to undergo surgical revision because of infections, dislocations, or unacceptable electrical behavior manifested as high threshold, unstable sensing, or unwanted phrenic nerve stimulation. CASE REPORT A 70-year-old man with symptomatic congestive heart failure underwent implantation of a biventricular pacemaker on the left anterior chest wall in 2003 and pulse generator exchange in August 2009. The patient responded well to CRT. At follow-up, the pacing system functioned normally. In September 2009, in the context of a predialysis program, an abdominal computed tomography (CT) scan was performed in another hospital for assessment and evaluation of chronic kidney disease. This procedure was complicated with peripheral thrombophlebitis that was managed appropriately with complete recovery. Eight months later (May 2010), the patient was admitted to our hospital with fever, anemia, and elevated infection parameters. During admission, blood cultures grew Staphylococcus epidermidis. The chest X-ray, lung perfusion scintigraphy, and CT scan depicted pulmonary embolism and infarction. The right ventricular lead threshold was found to be increased to 7 volts with unsuccessful capture. Echocardiography demonstrated vegetations on leads. The entire pacing system was explanted, but the patient expired few days later following percutaneous removal due to multiorgan failure. CONCLUSIONS In heart failure, replacement of the CRT device may be complicated by bacterial endocarditis. As noted from this case report, sudden elevation of the pacing lead threshold should prompt thorough and immediate investigation to unravel its causes, not only the electrical characteristics but also the anatomical features.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app