A randomized controlled study comparing a vessel sealing system with the conventional technique in axillary lymph node dissection for primary breast cancer.
SpringerPlus 2016
OBJECTIVE: This study aimed to compare the efficacy and safety of the newest bipolar vessel sealing system (BVSS; LigaSure™ Small Jaw) to that of conventional technique in axillary dissection.
METHODS: Sixty-one patients with breast cancer were randomized to a conventional dissection surgical technique (CONV group; n = 30) by scalpel and monopolar cautery or that using a vessel sealing system (BVSS group; n = 31).
RESULTS: There was a significant difference between both groups in the mean number of days until drain removal (6.4 ± 2.9 vs. 8.2 ± 3.8 days; P value = 0.033), and the mean total volume of drainage fluid (365.3 ± 242.2 vs. 625.1 ± 446.6 mL; P value = 0.009). The incidence of seroma was similar in both groups (43.3 vs. 37.9 %; P value = 0.673). There was no statistically significant difference in axillary dissection operating time (66 vs. 70 min; P value = 0.371), or the mean volume of blood loss (18.2 ± 31.1 vs. 20.6 ± 26.3 mL; P value = 0.663).
CONCLUSIONS: Our results suggest that BVSS is a more effective device when compared to the conventional techniques in axillary dissection.
METHODS: Sixty-one patients with breast cancer were randomized to a conventional dissection surgical technique (CONV group; n = 30) by scalpel and monopolar cautery or that using a vessel sealing system (BVSS group; n = 31).
RESULTS: There was a significant difference between both groups in the mean number of days until drain removal (6.4 ± 2.9 vs. 8.2 ± 3.8 days; P value = 0.033), and the mean total volume of drainage fluid (365.3 ± 242.2 vs. 625.1 ± 446.6 mL; P value = 0.009). The incidence of seroma was similar in both groups (43.3 vs. 37.9 %; P value = 0.673). There was no statistically significant difference in axillary dissection operating time (66 vs. 70 min; P value = 0.371), or the mean volume of blood loss (18.2 ± 31.1 vs. 20.6 ± 26.3 mL; P value = 0.663).
CONCLUSIONS: Our results suggest that BVSS is a more effective device when compared to the conventional techniques in axillary dissection.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app