We have located links that may give you full text access.
A multi-resolution approach to localize neural sources of P300 event-related brain potential.
Computer Methods and Programs in Biomedicine 2016 September
BACKGROUND AND OBJECTIVE: P300 is probably the most well-known component of event-related brain potentials (ERPs). Using an oddball paradigm, a P300 component can be identified, that is, elicited by the target stimuli recognition. Since P300 is associated with attention and memory operations of the brain, investigation of this component can improve our understanding of these mechanisms. The present study is aimed at identifying the P300 generators in 30 healthy subjects aged 18-30 years using time-reduction region-suppression linearly constrained minimum variance (TR-LCMV) beamformer.
METHODS: In our study, TR-LCMV beamformer with multi-resolution approach is proposed, coarse-resolution space to find the approximated coherent source locations, fine-resolution space to estimate covariance matrix for dimension reduction of determined regions, and normal-resolution space to localize the P300 generators in the brain.
RESULTS: Our results over simulated and real data showed that this approach is a suitable tool to the analysis of ERP fields with localizing superior and inferior frontal lobe, middle temporal gyrus, parietal lobe, and cingulate gyrus as the most prominent sources of P300. The result of P300 localization was finally compared with the other localization methods and it is demonstrated that enhanced performance is achieved.
CONCLUSIONS: Our results showed that the P300 originates from a widespread neuronal network in the brain and not from a specific region. Our finding over simulated and real data demonstrated the ability of the TR-LCMV algorithm for P300 source localization.
METHODS: In our study, TR-LCMV beamformer with multi-resolution approach is proposed, coarse-resolution space to find the approximated coherent source locations, fine-resolution space to estimate covariance matrix for dimension reduction of determined regions, and normal-resolution space to localize the P300 generators in the brain.
RESULTS: Our results over simulated and real data showed that this approach is a suitable tool to the analysis of ERP fields with localizing superior and inferior frontal lobe, middle temporal gyrus, parietal lobe, and cingulate gyrus as the most prominent sources of P300. The result of P300 localization was finally compared with the other localization methods and it is demonstrated that enhanced performance is achieved.
CONCLUSIONS: Our results showed that the P300 originates from a widespread neuronal network in the brain and not from a specific region. Our finding over simulated and real data demonstrated the ability of the TR-LCMV algorithm for P300 source localization.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app