The Diagnostic Accuracy of Special Tests for Rotator Cuff Tear: The ROW Cohort Study.
OBJECTIVE: The aim was to assess diagnostic accuracy of 15 shoulder special tests for rotator cuff tears.
DESIGN: From February 2011 to December 2012, 208 participants with shoulder pain were recruited in a cohort study.
RESULTS: Among tests for supraspinatus tears, Jobe test had a sensitivity of 88% (95% confidence interval [CI], 80%-96%), specificity of 62% (95% CI, 53%-71%), and likelihood ratio of 2.30 (95% CI, 1.79-2.95). The full can test had a sensitivity of 70% (95% CI, 59%-82%) and a specificity of 81% (95% CI, 74%-88%). Among tests for infraspinatus tears, external rotation lag signs at 0 degrees had a specificity of 98% (95% CI, 96%-100%) and a likelihood ratio of 6.06 (95% CI, 1.30-28.33), and the Hornblower sign had a specificity of 96% (95% CI, 93%-100%) and likelihood ratio of 4.81 (95% CI, 1.60-14.49).
CONCLUSIONS: Jobe test and full can test had high sensitivity and specificity for supraspinatus tears, and Hornblower sign performed well for infraspinatus tears. In general, special tests described for subscapularis tears have high specificity but low sensitivity. These data can be used in clinical practice to diagnose rotator cuff tears and may reduce the reliance on expensive imaging.
DESIGN: From February 2011 to December 2012, 208 participants with shoulder pain were recruited in a cohort study.
RESULTS: Among tests for supraspinatus tears, Jobe test had a sensitivity of 88% (95% confidence interval [CI], 80%-96%), specificity of 62% (95% CI, 53%-71%), and likelihood ratio of 2.30 (95% CI, 1.79-2.95). The full can test had a sensitivity of 70% (95% CI, 59%-82%) and a specificity of 81% (95% CI, 74%-88%). Among tests for infraspinatus tears, external rotation lag signs at 0 degrees had a specificity of 98% (95% CI, 96%-100%) and a likelihood ratio of 6.06 (95% CI, 1.30-28.33), and the Hornblower sign had a specificity of 96% (95% CI, 93%-100%) and likelihood ratio of 4.81 (95% CI, 1.60-14.49).
CONCLUSIONS: Jobe test and full can test had high sensitivity and specificity for supraspinatus tears, and Hornblower sign performed well for infraspinatus tears. In general, special tests described for subscapularis tears have high specificity but low sensitivity. These data can be used in clinical practice to diagnose rotator cuff tears and may reduce the reliance on expensive imaging.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app