Self-monitoring and self-management of oral anticoagulation.
Cochrane Database of Systematic Reviews 2016 July 6
BACKGROUND: The introduction of point-of-care devices for the management of patients on oral anticoagulation allows self-testing by the patient at home. Patients who self-test can either adjust their medication according to a pre-determined dose-INR (international normalized ratio) schedule (self-management), or they can call a clinic to be told the appropriate dose adjustment (self-monitoring). Increasing evidence suggests self-testing of oral anticoagulant therapy is equal to or better than standard monitoring. This is an updated version of the original review published in 2010.
OBJECTIVES: To evaluate the effects on thrombotic events, major haemorrhages, and all-cause mortality of self-monitoring or self-management of oral anticoagulant therapy compared to standard monitoring.
SEARCH METHODS: For this review update, we re-ran the searches of the Cochrane Central Register of Controlled Trials (CENTRAL), 2015, Issue 6, the Cochrane Library, MEDLINE (Ovid, 1946 to June week 4 2015), Embase (Ovid, 1980 to 2015 week 27) on 1 July 2015. We checked bibliographies and contacted manufacturers and authors of relevant studies. We did not apply any language restrictions .
SELECTION CRITERIA: Outcomes analysed were thromboembolic events, mortality, major haemorrhage, minor haemorrhage, tests in therapeutic range, frequency of testing, and feasibility of self-monitoring and self-management.
DATA COLLECTION AND ANALYSIS: Review authors independently extracted data and we used a fixed-effect model with the Mantzel-Haenzel method to calculate the pooled risk ratio (RR) and Peto's method to verify the results for uncommon outcomes. We examined heterogeneity amongst studies with the Chi(2) and I(2) statistics and used GRADE methodology to assess the quality of evidence.
MAIN RESULTS: We identified 28 randomised trials including 8950 participants (newly incorporated in this update: 10 trials including 4227 participants). The overall quality of the evidence was generally low to moderate. Pooled estimates showed a reduction in thromboembolic events (RR 0.58, 95% CI 0.45 to 0.75; participants = 7594; studies = 18; moderate quality of evidence). Both, trials of self-management or self-monitoring showed reductions in thromboembolic events (RR 0.47, 95% CI 0.31 to 0.70; participants = 3497; studies = 11) and (RR 0.69, 95% CI 0.49 to 0.97; participants = 4097; studies = 7), respectively; the quality of evidence for both interventions was moderate. No reduction in all-cause mortality was found (RR 0.85, 95% CI 0.71 to 1.01; participants = 6358; studies = 11; moderate quality of evidence). While self-management caused a reduction in all-cause mortality (RR 0.55, 95% CI 0.36 to 0.84; participants = 3058; studies = 8); self-monitoring did not (RR 0.94, 95% CI 0.78 to 1.15; participants = 3300; studies = 3); the quality of evidence for both interventions was moderate. In 20 trials (8018 participants) self-monitoring or self-management did not reduce major haemorrhage (RR 0.95, 95% CI, 0.80 to 1.12; moderate quality of evidence). There was no significant difference found for minor haemorrhage (RR 0.97, 95% CI 0.67 to 1.41; participants = 5365; studies = 13). The quality of evidence was graded as low because of serious risk of bias and substantial heterogeneity (I(2) = 82%).
AUTHORS' CONCLUSIONS: Participants who self-monitor or self-manage can improve the quality of their oral anticoagulation therapy. Thromboembolic events were reduced, for both those self-monitoring or self-managing oral anticoagulation therapy. A reduction in all-cause mortality was observed in trials of self-management but not in self-monitoring, with no effects on major haemorrhage.
OBJECTIVES: To evaluate the effects on thrombotic events, major haemorrhages, and all-cause mortality of self-monitoring or self-management of oral anticoagulant therapy compared to standard monitoring.
SEARCH METHODS: For this review update, we re-ran the searches of the Cochrane Central Register of Controlled Trials (CENTRAL), 2015, Issue 6, the Cochrane Library, MEDLINE (Ovid, 1946 to June week 4 2015), Embase (Ovid, 1980 to 2015 week 27) on 1 July 2015. We checked bibliographies and contacted manufacturers and authors of relevant studies. We did not apply any language restrictions .
SELECTION CRITERIA: Outcomes analysed were thromboembolic events, mortality, major haemorrhage, minor haemorrhage, tests in therapeutic range, frequency of testing, and feasibility of self-monitoring and self-management.
DATA COLLECTION AND ANALYSIS: Review authors independently extracted data and we used a fixed-effect model with the Mantzel-Haenzel method to calculate the pooled risk ratio (RR) and Peto's method to verify the results for uncommon outcomes. We examined heterogeneity amongst studies with the Chi(2) and I(2) statistics and used GRADE methodology to assess the quality of evidence.
MAIN RESULTS: We identified 28 randomised trials including 8950 participants (newly incorporated in this update: 10 trials including 4227 participants). The overall quality of the evidence was generally low to moderate. Pooled estimates showed a reduction in thromboembolic events (RR 0.58, 95% CI 0.45 to 0.75; participants = 7594; studies = 18; moderate quality of evidence). Both, trials of self-management or self-monitoring showed reductions in thromboembolic events (RR 0.47, 95% CI 0.31 to 0.70; participants = 3497; studies = 11) and (RR 0.69, 95% CI 0.49 to 0.97; participants = 4097; studies = 7), respectively; the quality of evidence for both interventions was moderate. No reduction in all-cause mortality was found (RR 0.85, 95% CI 0.71 to 1.01; participants = 6358; studies = 11; moderate quality of evidence). While self-management caused a reduction in all-cause mortality (RR 0.55, 95% CI 0.36 to 0.84; participants = 3058; studies = 8); self-monitoring did not (RR 0.94, 95% CI 0.78 to 1.15; participants = 3300; studies = 3); the quality of evidence for both interventions was moderate. In 20 trials (8018 participants) self-monitoring or self-management did not reduce major haemorrhage (RR 0.95, 95% CI, 0.80 to 1.12; moderate quality of evidence). There was no significant difference found for minor haemorrhage (RR 0.97, 95% CI 0.67 to 1.41; participants = 5365; studies = 13). The quality of evidence was graded as low because of serious risk of bias and substantial heterogeneity (I(2) = 82%).
AUTHORS' CONCLUSIONS: Participants who self-monitor or self-manage can improve the quality of their oral anticoagulation therapy. Thromboembolic events were reduced, for both those self-monitoring or self-managing oral anticoagulation therapy. A reduction in all-cause mortality was observed in trials of self-management but not in self-monitoring, with no effects on major haemorrhage.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app