An Experimental and Computational Study on the Effect of Caval Valved Stent Oversizing.
Cardiovascular Engineering and Technology 2016 September
Heterotopic implantation of transcatheter tricuspid valve is a new treatment option for tricuspid regurgitation. Transcatheter tricuspid valves are implanted onto the cavoatrial junction in order to avoid the challenging task of anchoring the valve onto the complex tricuspid valve annulus. However, little is known about optimum extent of oversizing of the valved stent in a vena cava. In this study, we implanted valves of the same diameter onto the larger sized inferior vena cava (IVC) and a smaller sized superior vena cava (SVC). The valve in the IVC was oversized by 10.7% while the valve in the SVC was oversized by 21.6%. Finite element analysis was performed (i) to assess the strain on the nitinol stent during manufacturing and deployment; (ii) the stents were deployed in a patient-specific vena cava model and the intramural stress of the vena cava was calculated computationally. These valves were fabricated and placed in a silicone model of a patient-specific right atrium which was part of a mock circulatory system that emulated the patho-physiological flow rate and pressure of a patient with tricuspid regurgitation. Flow measurements were conducted by particle image velocimetry (PIV). It was found that the maximum crimping strain on the nitinol stent was 6.85% which was lower than the critical threshold of 10%. The maximum stress on the vena cava was located at the spot where the hooks met the wall. The maximum stress on the IVC was 0.5098 MPa while the maximum stress on the SVC was 0.7 MPa. The maximum Reynolds shear stress (mRSS) in the vena cava was found to be higher in the IVC than SVC with the highest mRSS being 1741 dynes/cm(2) found in the region of high flow during the peak flow phase. The overtly oversized valve in the SVC did not cause flow disturbances and exhibited mostly laminar flows. The mRSS at the downstream of the vena cava valve and the middle of the atrium remained at low magnitudes. However, velocity fluctuations were high in the IVC in all the time points measured. In conclusion, oversizing the valve may assist anchorage; yet, careful consideration should be taken in choosing the extent of oversizing as it may lead to adverse effects.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app