We have located links that may give you full text access.
Calculation of posterior chamber intraocular lens (IOL) size and dioptric power for use in pet rabbits undergoing phacoemulsification.
Veterinary Ophthalmology 2017 May
OBJECTIVES: To calculate the size and dioptric power of a posterior chamber intraocular lens (IOL) to achieve emmetropia in adult rabbits and to compare the dioptric power calculation results using a proprietary predictive formula to a retinoscopy-based method.
ANIMALS STUDIED: Three wild rabbit cadavers, seven pet rabbits with cataracts and ten healthy pet rabbits.
MATERIALS AND METHODS: Implant size was calculated using a capsular tension ring (CTR) (Acrivet® , Berlin, Germany). Published and cadaveric biometric data were used in the predictive formula. An IOL power-escalation study compared the predicted values to the refraction results of one pet rabbit (P1) fitted with a + 41D canine IOL (Acrivet® ) and six pet rabbits (P2-P7) fitted with prototype IOLs (Acrivet® ). Retinoscopy of 10 healthy pet rabbits served as controls.
RESULTS: A 13.5 mm CTR fitted in all rabbits and permitted the use of a 13 mm IOL. The predicted IOL power ranged between +24D and +25D. The +41D IOL resulted in a refraction error of +8D. Progressive recalculation through a calibration formula led to the insertion of three +49D IOLs in two pet rabbits and a refraction of +6D to +8D, followed by seven +58D IOLs in four pet rabbits and a refraction median of 0D (range: -1.5D to +1D).
CONCLUSIONS: A 13 mm prototype IOL of +58D achieves emmetropia and is of adequate size for rabbits. The combined use of a CTR and retinoscopy is a useful method to calculate the size and refractive power of a new, species-specific, veterinary IOL.
ANIMALS STUDIED: Three wild rabbit cadavers, seven pet rabbits with cataracts and ten healthy pet rabbits.
MATERIALS AND METHODS: Implant size was calculated using a capsular tension ring (CTR) (Acrivet® , Berlin, Germany). Published and cadaveric biometric data were used in the predictive formula. An IOL power-escalation study compared the predicted values to the refraction results of one pet rabbit (P1) fitted with a + 41D canine IOL (Acrivet® ) and six pet rabbits (P2-P7) fitted with prototype IOLs (Acrivet® ). Retinoscopy of 10 healthy pet rabbits served as controls.
RESULTS: A 13.5 mm CTR fitted in all rabbits and permitted the use of a 13 mm IOL. The predicted IOL power ranged between +24D and +25D. The +41D IOL resulted in a refraction error of +8D. Progressive recalculation through a calibration formula led to the insertion of three +49D IOLs in two pet rabbits and a refraction of +6D to +8D, followed by seven +58D IOLs in four pet rabbits and a refraction median of 0D (range: -1.5D to +1D).
CONCLUSIONS: A 13 mm prototype IOL of +58D achieves emmetropia and is of adequate size for rabbits. The combined use of a CTR and retinoscopy is a useful method to calculate the size and refractive power of a new, species-specific, veterinary IOL.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app