We have located links that may give you full text access.
Intraosseous access in the obese patient: assessing the need for extended needle length.
American Journal of Emergency Medicine 2016 September
BACKGROUND: Intraosseous (IO) access can be complicated by obesity. Successful placement of a 25 mm IO needle is unlikely when soft tissue depth exceeds 20 mm.
OBJECTIVES: The authors examined the relationship between body mass index (BMI), the ability to palpate the tibial tuberosity (TT), and soft tissue depth at recommended IO insertion sites.
METHODS: Obese emergency department patients were assessed for a palpable TT and received ultrasound measurement of the soft tissue depth at recommended IO insertion sites. Linear and logistic regression were used to determine cut-off BMI values predicting soft tissue depth >20 mm.
RESULTS: Seventy-five patients were enrolled with a mean BMI of 47.2. The mean soft tissue depth at the proximal humerus, proximal tibial, and distal tibial were 29.6 [95% CI 27.5-31.7] mm, 11.0 [8.9-13.0] mm, and 10.7 [9.4-12.1] mm, respectively. In 5 patients without a palpable TT the soft tissue depth exceeded 20 mm at all three anatomic sites. A BMI ≥43 and BMI ≥60 predicted a soft tissue depth >20 mm at the proximal tibia and distal tibia, respectively, while no reliable BMI cut-off was identified at the proximal humerus.
CONCLUSIONS: In obese adults with a palpable TT or BMI ≤43 a 25 mm IO needle is likely adequate at the proximal and distal tibial insertion sites. Empiric use of an extended 45 mm IO needle is advisable at the proximal humeral insertion site in obese patients.
OBJECTIVES: The authors examined the relationship between body mass index (BMI), the ability to palpate the tibial tuberosity (TT), and soft tissue depth at recommended IO insertion sites.
METHODS: Obese emergency department patients were assessed for a palpable TT and received ultrasound measurement of the soft tissue depth at recommended IO insertion sites. Linear and logistic regression were used to determine cut-off BMI values predicting soft tissue depth >20 mm.
RESULTS: Seventy-five patients were enrolled with a mean BMI of 47.2. The mean soft tissue depth at the proximal humerus, proximal tibial, and distal tibial were 29.6 [95% CI 27.5-31.7] mm, 11.0 [8.9-13.0] mm, and 10.7 [9.4-12.1] mm, respectively. In 5 patients without a palpable TT the soft tissue depth exceeded 20 mm at all three anatomic sites. A BMI ≥43 and BMI ≥60 predicted a soft tissue depth >20 mm at the proximal tibia and distal tibia, respectively, while no reliable BMI cut-off was identified at the proximal humerus.
CONCLUSIONS: In obese adults with a palpable TT or BMI ≤43 a 25 mm IO needle is likely adequate at the proximal and distal tibial insertion sites. Empiric use of an extended 45 mm IO needle is advisable at the proximal humeral insertion site in obese patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app