Short-Term Adaptation of Accommodative Responses in Myopes Fitted With Multifocal Contact Lenses.

Eye & Contact Lens 2018 September
OBJECTIVES: To investigate whether adaptation of accommodative responses occurred in non-presbyopic myopes fitted with four multifocal contact lens (MFCL) designs.

METHODS: Prospective, subject-masked clinical investigation comprising 40 experienced myopic lens wearers (18-25 years) fitted bilaterally with single-vision (SV) control lens (Air Optix Aqua [Alcon, Fort Worth, TX]) and randomized to two of four test MFCL (Proclear MFCL [Distance and Near] [CooperVision, Pleasanton, CA], Air Optix Aqua MFCL, Purevision MFCL [Bausch & Lomb, Rochester, NY]). Lenses were dispensed on a daily wear basis and worn for a minimum of 8 (maximum 14) days over three assessment visits, with a 1-week wash out between stages. Paraxial curvature matched spherical equivalent (M) was measured with lenses on eye using the BHVI-EyeMapper with an internal movable fixation target positioned at target vergences of +1.00 diopter (D) (fogging) and -2.00 to -5.00 in 1.00 D steps (accommodative stimuli). Accommodative facility was assessed by several flips of ±2.00 D/min (cycles/min) at 33 cm and horizontal phoria with a Howell phoria card at distance (3 m) and near (33 cm).

RESULTS: For center-distance MFCL (Proclear D), the spherical equivalent (M) at all near vergences became significantly more negative at the follow-up visits compared with the dispensing visit (P<0.029). For all center-near MFCLs and SV lens, M remained invariant during the adaptation period, however (P≥0.267). At distance, M became significantly less minus with Air Optix Aqua MFCL over time (P=0.049). Accommodative facility increased over the three assessment visits for participants wearing Air Optix Aqua SV, Air Optix Aqua MFCL, and PureVision MFCL (P=0.003). Distance and near horizontal phoria remained stable over the three assessment visits for all lens types (P≥0.181).

CONCLUSIONS: Adaptation differences were not consistently found for static accommodative measures gauged by M, as measured with lenses on eye, and phoria but were found in dynamic measures (facility), perhaps indicating some learning effects. Accommodative adaptation seems unlikely to occur with long-term MFCL in non-presbyopes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app