We have located links that may give you full text access.
Surface Treatment by Different Parameters of Erbium:Yttrium-Aluminum-Garnet (Er:YAG) Laser: Scanning Electron Microscope (SEM) Evaluation.
INTRODUCTION: This study aimed to assess the Scanning Electron Microscope (SEM) analysis of tooth surface irradiated by erbium:yttrium-aluminum-garnet (Er:YAG) laser with various parameters.
METHODS: Number of 25 extracted human third molars free of caries were used in this study. The teeth were put into 5 groups for laser irradiation as follows: group 1 (power: 0.5 W, Energy: 50 mJ); group 2 (power: 1 W, Energy: 100 mJ); group 3 (power: 1.5 W, Energy: 150 mJ); group 4 (power: 2 W, Energy: 200 mJ); group 5 (power: 2.5 W, Energy: 250 mJ). All samples were prepared by repetition rate of 10 Hz and duration of 230 μs, using a non-contact handpiece at a distance of 4 mm. Then, the samples were prepared for SEM examination.
RESULTS: SEM evaluation of every 25 samples, treated by Er:YAG, showed that all groups had exposed dentinal tubules without any melted area or cracks.
CONCLUSION: In this study we used SEM to investigate ablated dentine with different parameters of Er:YAG laser energy. Our findings support these conclusions. All powers of laser below 3 W are proper for ablation, and make no cracks.
METHODS: Number of 25 extracted human third molars free of caries were used in this study. The teeth were put into 5 groups for laser irradiation as follows: group 1 (power: 0.5 W, Energy: 50 mJ); group 2 (power: 1 W, Energy: 100 mJ); group 3 (power: 1.5 W, Energy: 150 mJ); group 4 (power: 2 W, Energy: 200 mJ); group 5 (power: 2.5 W, Energy: 250 mJ). All samples were prepared by repetition rate of 10 Hz and duration of 230 μs, using a non-contact handpiece at a distance of 4 mm. Then, the samples were prepared for SEM examination.
RESULTS: SEM evaluation of every 25 samples, treated by Er:YAG, showed that all groups had exposed dentinal tubules without any melted area or cracks.
CONCLUSION: In this study we used SEM to investigate ablated dentine with different parameters of Er:YAG laser energy. Our findings support these conclusions. All powers of laser below 3 W are proper for ablation, and make no cracks.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app