Add like
Add dislike
Add to saved papers

Optimizing the detection of methicillin-resistant Staphylococcus aureus with elevated vancomycin minimum inhibitory concentrations within the susceptible range.

BACKGROUND: Determination of vancomycin minimum inhibitory concentration (MIC) can influence the agent used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. We studied diagnostic accuracy using E-test and VITEK(®) 2 against a gold standard broth microdilution (BMD) methodology, the correlation between methods, and associations between vancomycin MIC and MRSA phenotype from clinical isolates.

METHODS: MRSA isolates were obtained from April 2012 to December 2013. Vancomycin MIC values were determined prospectively on all isolates by gradient diffusion E-test and automated VITEK(®) 2. The Clinical and Laboratory Standards Institute reference BMD method was performed retrospectively on thawed frozen isolates. Diagnostic accuracy for detecting less susceptible strains was calculated at each MIC cutoff point for E-Test and VITEK(®) 2 using BMD ≥1 µg/mL as a standard. The correlation between methods was assessed using Spearman's rho (ρ). The association between MRSA phenotype and MIC for the three methods was assessed using Fisher's exact test.

RESULTS: Of 148 MRSA isolates, all except one (E-test =3 µg/mL) were susceptible to vancomycin (MIC of ≤2 µg/mL) irrespective of methodology. MICs were ≥1.0 µg/mL for 9.5% of BMD, 50.0% for VITEK(®) 2, and 27.7% for E-test. Spearman's ρ showed weak correlations between methods: 0.29 E-test vs VITEK(®) 2 (P=0.003), 0.27 E-test vs BMD (P=0.001), and 0.31 VITEK(®) 2 vs BMD (P=0.002). The optimal cutoff points for detecting BMD-defined less susceptible strains were ≥1.0 µg/mL for E-test and VITEK(®) 2. E-test sensitivity at this cutoff point was 0.85 and specificity 0.29, while VITEK(®) 2 sensitivity and specificity were 0.62 and 0.51, respectively. Multiresistant MRSA strains tended to have higher MIC values compared to nonmultiresistant MRSA or epidemic MRSA 15 phenotypes by E-test (Fisher's exact P<0.001) and VITEK(®) 2 (Fisher's exact P<0.001).

CONCLUSION: Overall diagnostic accuracy and correlations between MIC methods used in routine diagnostic laboratories and the gold standard BMD showed limited overall agreement. This study helps optimize guidance on the effective use of vancomycin.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app