We have located links that may give you full text access.
Assessment of cerebral venous sinus thrombosis using T2 (*)-weighted gradient echo magnetic resonance imaging sequences.
Iranian Journal of Neurology 2016 April 4
BACKGROUND: The purpose of this study is to demonstrate the advantages of gradient echo (GRE) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences.
METHODS: A total of 17 patients with cerebral venous thrombosis (CVT) were evaluated using different magnetic resonance imaging (MRI) sequences. The MRI sequences included T1-weighted spin echo (SE) imaging, T(*) 2-weighted turbo SE (TSE), fluid attenuated inversion recovery (FLAIR), T(*) 2-weighted conventional GRE, and diffusion weighted imaging (DWI). MR venography (MRV) images were obtained as the golden standard.
RESULTS: Venous sinus thrombosis was best detectable in T(*) 2-weighted conventional GRE sequences in all patients except in one case. Venous thrombosis was undetectable in DWI. T(*) 2-weighted GRE sequences were superior to T(*) 2-weighted TSE, T1-weighted SE, and FLAIR. Enhanced MRV was successful in displaying the location of thrombosis.
CONCLUSION: T(*) 2-weighted conventional GRE sequences are probably the best method for the assessment of cerebral venous sinus thrombosis. The mentioned method is non-invasive; therefore, it can be employed in the clinical evaluation of cerebral venous sinus thrombosis.
METHODS: A total of 17 patients with cerebral venous thrombosis (CVT) were evaluated using different magnetic resonance imaging (MRI) sequences. The MRI sequences included T1-weighted spin echo (SE) imaging, T(*) 2-weighted turbo SE (TSE), fluid attenuated inversion recovery (FLAIR), T(*) 2-weighted conventional GRE, and diffusion weighted imaging (DWI). MR venography (MRV) images were obtained as the golden standard.
RESULTS: Venous sinus thrombosis was best detectable in T(*) 2-weighted conventional GRE sequences in all patients except in one case. Venous thrombosis was undetectable in DWI. T(*) 2-weighted GRE sequences were superior to T(*) 2-weighted TSE, T1-weighted SE, and FLAIR. Enhanced MRV was successful in displaying the location of thrombosis.
CONCLUSION: T(*) 2-weighted conventional GRE sequences are probably the best method for the assessment of cerebral venous sinus thrombosis. The mentioned method is non-invasive; therefore, it can be employed in the clinical evaluation of cerebral venous sinus thrombosis.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app