We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Echocardiographic Ischemic Memory Imaging Through Complement-Mediated Vascular Adhesion of Phosphatidylserine-Containing Microbubbles.
JACC. Cardiovascular Imaging 2016 August
OBJECTIVES: This study hypothesized that microvascular retention of phosphatidylserine-containing microbubbles (MB-PS) would allow detection of recent but resolved myocardial ischemia with myocardial contrast echocardiographic (MCE) molecular imaging.
BACKGROUND: Techniques for ischemic memory imaging which can detect and spatially assess resolved myocardial ischemia are being developed for rapid evaluation of patients with chest pain.
METHODS: MCE molecular imaging with MB-PS was performed 1.5 h, 3.0 h, and 6.0 h after brief (10 min) myocardial ischemia in mice; data were compared to selectin-targeted microbubbles. MCE molecular imaging with Sonazoid (GE Healthcare, Amersham, United Kingdom), a commercially produced phosphatidylserine (PS) - containing agent, was performed in separate mice at 1.5 h and 3.0 h after ischemia-reperfusion; and in dogs undergoing 135 min of ischemia and 60 min of reflow as well as in closed-chest nonischemic control dogs. The mechanism for MB-PS attachment was assessed by intravital microscopy of post-ischemic muscle and by flow cytometry analysis of cell-MB interactions.
RESULTS: In mice undergoing ischemia-reperfusion without infarction, signal enhancement in the risk area for MB-PS and p-selectin glycoprotein ligand-1-targeted microbubbles was similar at reflow times of 1.5 h (23.3 ± 7.3 IU vs. 30.7 ± 4.1 IU), 3.0 h (42.2 ± 6.2 IU vs. 33.9 ± 7.4 IU), and 6.0 h (24.1 ± 4.3 IU vs. 25.5 ± 4.7 IU). For both agents, signal in the risk area was significantly (p < 0.05) higher than remote region at all reflow times. Sonazoid also produced strong risk area enhancement at 1.5 h (34.7 ± 5.0 IU) and 3.0 h (52.5 ± 4.5 IU) which was approximately 3-fold greater than in the control region, and which correlated spatially with the microsphere-derived risk area. In dogs, Sonazoid signal in the risk area was >5-fold higher than in closed-chest control myocardium (42.2 ± 8.1 IU vs. 7.9 ± 3.3 IU; p < 0.001). Mechanistic studies indicated that MB-PS attached directly to venular endothelium and adherent leukocytes which was dependent on serum complement components C1q and C3.
CONCLUSIONS: Ischemic memory imaging with MCE is possible using MB-PS which may obviate the need for ligand-directed targeting.
BACKGROUND: Techniques for ischemic memory imaging which can detect and spatially assess resolved myocardial ischemia are being developed for rapid evaluation of patients with chest pain.
METHODS: MCE molecular imaging with MB-PS was performed 1.5 h, 3.0 h, and 6.0 h after brief (10 min) myocardial ischemia in mice; data were compared to selectin-targeted microbubbles. MCE molecular imaging with Sonazoid (GE Healthcare, Amersham, United Kingdom), a commercially produced phosphatidylserine (PS) - containing agent, was performed in separate mice at 1.5 h and 3.0 h after ischemia-reperfusion; and in dogs undergoing 135 min of ischemia and 60 min of reflow as well as in closed-chest nonischemic control dogs. The mechanism for MB-PS attachment was assessed by intravital microscopy of post-ischemic muscle and by flow cytometry analysis of cell-MB interactions.
RESULTS: In mice undergoing ischemia-reperfusion without infarction, signal enhancement in the risk area for MB-PS and p-selectin glycoprotein ligand-1-targeted microbubbles was similar at reflow times of 1.5 h (23.3 ± 7.3 IU vs. 30.7 ± 4.1 IU), 3.0 h (42.2 ± 6.2 IU vs. 33.9 ± 7.4 IU), and 6.0 h (24.1 ± 4.3 IU vs. 25.5 ± 4.7 IU). For both agents, signal in the risk area was significantly (p < 0.05) higher than remote region at all reflow times. Sonazoid also produced strong risk area enhancement at 1.5 h (34.7 ± 5.0 IU) and 3.0 h (52.5 ± 4.5 IU) which was approximately 3-fold greater than in the control region, and which correlated spatially with the microsphere-derived risk area. In dogs, Sonazoid signal in the risk area was >5-fold higher than in closed-chest control myocardium (42.2 ± 8.1 IU vs. 7.9 ± 3.3 IU; p < 0.001). Mechanistic studies indicated that MB-PS attached directly to venular endothelium and adherent leukocytes which was dependent on serum complement components C1q and C3.
CONCLUSIONS: Ischemic memory imaging with MCE is possible using MB-PS which may obviate the need for ligand-directed targeting.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app