Add like
Add dislike
Add to saved papers

Superiority of Deformable Image Co-registration in the Integration of Diagnostic Positron Emission Tomography-Computed Tomography to the Radiotherapy Treatment Planning Pathway for Oesophageal Carcinoma.

AIMS: To investigate the use of image co-registration in incorporating diagnostic positron emission tomography-computed tomography (PET-CT) directly into the radiotherapy treatment planning pathway, and to describe the pattern of local recurrence relative to the PET-avid volume.

MATERIALS AND METHODS: Fourteen patients were retrospectively identified, six of whom had local recurrence. The accuracy of deformable image registration (DIR) and rigid registration of the diagnostic PET-CT and recurrence CT, to the planning CT, were quantitatively assessed by comparing co-registration of oesophagus, trachea and aorta contours. DIR was used to examine the correlation between PET-avid volumes, dosimetry and site of recurrence.

RESULTS: Positional metrics including the dice similarity coefficient (DSC) and conformity index (CI), showed DIR to be superior to rigid registration in the co-registration of diagnostic and recurrence imaging to the planning CT. For diagnostic PET-CT, DIR was superior to rigid registration in the transfer of oesophagus (DSC=0.75 versus 0.65, P<0.009 and CI=0.59 versus 0.48, P<0.003), trachea (DSC=0.88 versus 0.65, P<0.004 and CI=0.78 versus 0.51, P<0.0001) and aorta structures (DSC=0.93 versus 0.86, P<0.006 and CI=0.86 versus 0.76, P<0.006). For recurrence imaging, DIR was superior to rigid registration in the transfer of trachea (DSC=0.91 versus 0.66, P<0.03 and CI=0.83 versus 0.51, P<0.02) and oesophagus structures (DSC=0.74 versus 0.51, P<0.004 and CI=0.61 versus 0.37, P<0.006) with a non-significant trend for the aorta (DSC=0.91 versus 0.75, P<0.08 and CI=0.83 versus 0.63, P<0.06) structure. A mean inclusivity index of 0.93 (range 0.79-1) showed that the relapse volume was within the planning target volume (PTVPET-CT); all relapses occurred within the high dose region.

CONCLUSION: DIR is superior to rigid registration in the co-registration of PET-CT and recurrence CT to the planning CT, and can be considered in the direct integration of PET-CT to the treatment planning process. Local recurrences occur within the PTVPET-CT, suggesting that this is a suitable target for dose-escalation strategies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app