The Asfora Bullet Cage System Shows Comparable Fusion Rate Success Versus Control Cage in Posterior Lumbar Interbody Fusion in a Randomized Clinical Trial.

BACKGROUND: Low back pain and degeneration of the intervertebral disc are an integrated malady that affects millions of Americans. Cage devices used in association with posterior lumbar interbody fusion (PLIF) have been shown to be an effective approach in the treatment of a number of lower spine disorders attributed to degenerative disc disease (DDD).

OBJECTIVE: This study was undertaken as part of a U.S. Food and Drug Administration (FDA) Investigational Device Exemption (IDE) study and compares the effectiveness of the Asfora Bullet Cage System (ABCS) to successfully fuse vertebra at one or two levels between L2 and S1 in patients with DDD to an FDA approved comparison device, the Medtronic-Sofamor Danek Inter Fix Threaded Fusion Device (MSDIFD).

METHODS: A total of 257 randomized participants were implanted with either the ABCS device (n = 132) or the MSDIFD device (n = 125) through an open posterior approach using autogenous local bone graft without the use of pedicle screws. Patients were evaluated prior to surgery and at the 24 month (24-M) visit for fusion status, deep tendon reflex status, sensory function, motor function, straight leg raise status, pain, disability, and device safety. Radiological evaluation and statistical analysis were performed by independent professionals.

RESULTS: Evaluation of device success was performed at 24-M visit. From the original group of 257 patients, 59 were lost to follow-up. Primary measures of success at the 24-M visit involved pain and function, fusion, neurological status, and device-related adverse events measures. Pain and function improved in both (MSDIFD: 75.7 percent; ABCS: 82.6 percent). Fusion success with all radiographic points at 24-M visits was 79.4 percent MSDIFD and 88.2 percent ABCS. Neurological improvement was seen in both (MSDIFD: 77.0 percent; ABCS: 87.8 percent). One device-related grade 1 adverse event was reported in the MSDIFD group. Disc height preservation was equivalent for single level fusions (MSDIFD: 16.1 percent; ABCS: 20.0 percent) and second level fusions (MSDIFD: 10.7 percent; ABCS: 14.3 percent). General health and well-being improvement was the same (MSDIFD: 37.0 percent; ABCS: 40.0 percent). Subsequent fusion, up to 10 years, was equivalent (MSDIFD: 83.8 percent; ABCS: 91.2). Results for both devices were considered to be satisfactory, with a slight non-significant superiority for the ABCS.

CONCLUSION: From the ABCS device FDA IDE sanctioned study and the review of the literature, we concluded that the Asfora Bullet Cage System is safe, effective and comparable to other interbody fusion devices which are used stand-alone or in conjunction with pedicle screws, rhBMP-2, or autogenous bone harvested from the iliac crest inserted through anterior, lateral or posterior approaches.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app